Manual
Double Sheet Detector R100 I100
for pairs of sensors
Start-up
B0003308 / 1.4 / 13.02.2013
36
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
6.8
Teach-In with changed threshold values
This function should only be performed if different threshold settings are to be used.
Preparation
:
A100: Place the sensor on the sheet.
I100: Place the sheet between the sensors.
Step 1
Press the key “setup“.
Fig. 28: Calling up the setup mode
R100structure.bmp
Step 2
Press the key “change“.
Fig. 29: Calling up a change
R100TChHandChange.bmp
Step 3
Press the key “renew“.
By pressing the key “renew” the Teach-In will be performed with the
modified settings.
The current measurement value is stored as reference value.
Based on the reference value the absolute values for the thresholds L
and U are calculated with the modified relative factors and be stored
also.
Fig. 30: Performing the Teach-In with modified values
R100TChangeHandRenew.bmp
Has the function been executed, the system automatically changes to the measurement mode and
shows the new thresholds.
If the function could not be executed, a fault message appears in the LCD display.