55
4 Adjustment
4
3
Raise the SHEET LOADING LEVER.
Press the [CUT TEST] key to enter the AUTOMATIC
ADJUSTMENT MODE.
All [CARTRIDGE HOLDER] LED will blink.
4
Install the DENSITY ADJUSTING SOFTWARE DISK in
your PC.
The DISK includes the following.
1. Program [PC60SPF.EXE] to download data.
2. Data file for the HEAD [???-????.TEI].
3. README.TXT
5
Send data file from MS-DOS by typing as below.
PC60SPF /L ???-????.TEI
[???-????] is the serial number of the HEAD. It is also
written on the HEAD as shown in the figure.
Example
B05-0051
PTMTM3207A
719A10
Serial Number : B05-0051
6
When the AUTOMATIC ADJUSTMENT is done properly,
[CARTRIDGE HOLDER] LED will be OFF from 1 to 6 in
order.
If NG, PC-60 repeats the following indication.
1. All LED blink 5 times.
2. [COLOR] and [CARTRIDGE HOLDER 1] LED
blinks once.
Содержание Color Camm Pro PC-60