Rola-Chem Digital Controller PN 554212 11/22/06 Page: 6 of 16
NOTE
:
When automating any body of water, it is essential to size the
feeders to reach desired levels in a relatively short period of time.
Generally, automating an existing body of water with existing feeders
will require the output of the feeders be increased accordingly. If
feeders are unable to keep up with demand in a short period of time,
automation becomes ineffective.
2.2 Specifications
Display:
pH 6.8 to 8.2
Control:
pH 7.0 to 8.0
Factory default:
pH 7.4
Input Power
120 Volts AC, 50/60 HZ, 3 wire grounded power cord.
GFCI source required
Output Power
120 Volts AC, 50/60 HZ, --5 amps (fused)
Two 3-wire grounded power receptacles
Terminal strip for hardwire applications.
Displays:
pH reading
– red digital LED
Flow/Power indicator
-green LED
Auto (operating mode) indicator -red LED
Alert indicator
-red LED
Feed indicator
-green LED
(NOTE- lamps flash during the feed time and are on constant
during the delay time of the feed cycle.)
O
perating
Temperature
:
40 to 120° F
Features and Options
+ pH setting
+ pH feed/delay time
+ alert (high & low)
+ Acid/base feed
+ calibration
+ Flow switch input
+ Feed time out
+ fused outputs