background image

Rola-Chem Digital Controller                  PN 554212      11/22/06                      Page: 13 of 16 

6.0 Warranty and Service-   

  
6.1 Limited Warrenty 
 

Rola-Chem Corporation warrants the original purchaser that this unit is 
free from manufacturing defects in material and workmanship from the 
date of the original purchase for one (1) year.  
If this unit fails within the one (1) year period, it will be repaired or 
replaced (Rola-Chem’s option) at no charge, when returned to Rola-
Chem Corporation with proof of purchase receipt. This warranty does 
not apply to any product damage caused by improper use, accident, 
misuse, improper line voltage, fire, flood, lightening, earthquake or 
other acts of nature, or, if product was altered or opened by anyone 
other than qualified Rola-Chem personnel.  
 
All expendable items- hoses, etc., are not covered under this warranty. 
 
Heavy duty probes are warranted from the date of original purchase for 
one (1) year. 
 
Rola-Chem Corporation, under no circumstances, shall be liable for any 
consequential damages directly or indirectly caused by this unit. Please 
observe all rules and regulations required by state and local regulations, 
building codes, health codes, OSHA, etc. 
 

6.2 Service Procedure

 

 

For operation assistance in the United State, please call: 

 (800) 549-4473 or FAX (651)-653-0989  

Monday thru Friday 8:00 am-5:00 pm, Central Time. 

 
Rola-Chem Corporation has specialized knowledge and equipment to 
properly test your unit and help you with special problems. After talking 
to our service personnel, the product in need of service should be 
shipped with RGA#, freight prepaid, via UPS if at all possible to: 

 

Rola-Chem Corporation 

5858 Centerville Road 

St. Paul, MN 55127-6804 

 
 

Содержание 554200

Страница 1: ...ODEL 554200 pH Digital Controller MODE FLOW SWITCH pH OUTPUT FEED TIME SET LEVEL pH pH CALIB POWER ALERT FEED pH AUTO FLOW Operating Manual Rola Chem Digital Controller PN 554212 11 22 06 Page 1 of 16...

Страница 2: ...operate in the factory preset settings Set level pH 7 4 Feed times 0 6 second feed with a 5 minute delay Limits Alerts pH 8 0 hi 7 0 low To Change Settings Press and release the mode button AUTO light...

Страница 3: ...5 2 2 Specifications 6 2 3 Description of controls 7 3 0 Installation 3 1 Locating the controller 8 3 2 Mechanical installation 8 3 3 Power access panel 8 3 3 1 Fuses 9 3 3 2 Flow Switch 9 3 3 3 Acid...

Страница 4: ...as a flow switch to shut off power from the controller in the event of pool pump or circulation failure It is not safe to automatically dispensed chemicals into a circulating system that is not runnin...

Страница 5: ...of pH chemicals The feed cycle is a timed based feed then delay system The controller has a series of fixed feed times 0 6 to 900 sec with associated delays as well as a constant feed mode con A feed...

Страница 6: ...trol pH 7 0 to 8 0 Factory default pH 7 4 Input Power 120 Volts AC 50 60 HZ 3 wire grounded power cord GFCI source required Output Power 120 Volts AC 50 60 HZ 5 amps fused Two 3 wire grounded power re...

Страница 7: ...witch is used When Flow light is on and Auto light is off levels can be set Set level button Pressing the set level button once will display the current set level To change the set level press the set...

Страница 8: ...ce Never mount a controller above or near an acid tank See appendix for typical feed system schematics 3 2 Mechanical Installation Once the site is selected obtain screws or anchors to securely mount...

Страница 9: ...nual Debris may obstruct flow switch and prevent the switch from functioning 3 3 3 Acid Base Feed Selection The controller has a terminal shipped with a jumper used to select acid or base chemical The...

Страница 10: ...s mode to maintain the desired parameters Timed feed settings The feed lamp will flash during the feed time and be constant during the delay time of the feed cycle Power will be supplied to feeder unt...

Страница 11: ...Simultaneously depress and hold the Set Level and pH Calib buttons C Turn the controller on by pushing the mode button D The display will read LD E Release the Set Level and pH Calib buttons F Turn t...

Страница 12: ...t points not being reached or maintained Factory setting for feed time is 0 6 sec on with 5 minute delay Feeders may require longer feed time If time is too short set points will not be maintained If...

Страница 13: ...ola Chem personnel All expendable items hoses etc are not covered under this warranty Heavy duty probes are warranted from the date of original purchase for one 1 year Rola Chem Corporation under no c...

Страница 14: ...the shielding effect for chlorine When using tri chlor recommended alkalinity is 95 125 ppm 7 2 Typical System Installations FILTER SAFETY FLOWSWITCH TO ENSURE CIRCULATION TO CONTROL PROBES AND INDIC...

Страница 15: ...Rola Chem Digital Controller PN 554212 11 22 06 Page 15 of 16 NOTES...

Страница 16: ...Rola Chem Digital Controller PN 554212 11 22 06 Page 16 of 16 NOTES...

Отзывы: