![Roiscok RP208KCL Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/roiscok/rp208kcl/rp208kcl_manual_1478649016.webp)
On/Off Audible Kiss-off
It is defaulted that RP248CN will give a long beep to remind disarm successfully. To on/off the
buzzer, press [*] + [4] + [master code] + [7] or [8].
3.10 Duress code disarm
If you are ever coerced to disarm your system, you can comply with the intruder’s wishes while
sending a silent, duress alarm, to the Central Station. To do so, you must use a special Duress
Code.
Which when used, will disarm the system in the regular manner, while simultaneously transmitting
a silent alarm to the central station. All 10 codes (including one Master Code and 9 User Codes)
can activate the Duress disarming by adding 1 to The last digit of your user codes. The Duress
Code and the User code share the first 3 digits. Example:
User code =1-2-3-4; duress code is 1-2-3-5
User code =5-6-7-8; duress code is 5-6-7-9
User code= 7-8-9-0; duress code is 7-8-9-1
Note: Under no circumstances must the Duress Code be used haphazardly or without reason.
Central Stations, along with Police Departments, treat Duress Codes very seriously and take
immediate action.
3.11 Stop siren/bell and stop dialing a number
If outside premises, open an entry door; the keypad(s) will beep indicating that the Entry Delay
period has begun. The entry delay is defaulted as 30 seconds.
Silencing an alarm in progress
Observe the keypad. If any of the following conditions is evident, an alarm has occurred:
The ARM LED is flashing
Z1,Z2,Z3… are displayed on the LCD
It's best to enter the premises only after police or a security company has investigated and you feel
confident that the burglar is no longer on your premises.
3.12 Bypass and un-bypass zone(s)
Check the zone status
RP248CN User’s and Installer’s Manual