5.3.3 Monitoring Calibration Status
The current state of the ADR calibration will be continuously reported from
R&S ROMES software. Please refer to the R&S ROMES manual for details.
For requesting the status of the ADR calibration, please refer to section
on page 36.
There are different steps for calibration
•
No calibration
•
not yet calibrated
(
Calibrating
)
•
coarsely calibrated
(
Coarse Calib
)
•
finely calibrated
(
Fine Calib
)
Minimal calibration state for ADR
A sufficient ADR performance can be expected when at least coarse
calibration has been achieved.
Fine calibration isn’t mandatory for ADR assistance.
If the calibration status reaches “
Fine Calibration”
the user can expect very good
ADR functionality and the device will use this feature to improve the accuracy
respectively to bridge short times with poor or missing GPS reception.
How to see if ADR works properly?
ROMES:
the ADR state will be reported in the GPS status view (see R&S ROMES
documentation for details).
u-Center
: whether ADR is used is displayed in the “Data View” of the u-center
software
Figure 5-1: GPS status overview
If calibration does not start measurement see troubleshooting section
on page 41.