Remote Control
R&S
®
FPC
258
User Manual 1178.4130.02 ─ 07
[SENSe:]CORRection:TRANsducer<td>:UNIT?
This command queries the unit of the current transducer factor.
Prerequisites for this command
●
[SENSe:]CORRection:TRANsducer<td>:SELect
).
Suffix:
<td>
.
Return values:
<Unit>
Example:
//Query the unit of the primary transducer
CORR:TRAN1:SEL 'HE200A-20-200.pritrd'
CORR:TRAN1:UNIT?
Usage:
Query only
Manual operation:
See
[SENSe:]CORRection:TRANsducer<td>[:STATe]
<State>
This command turns a transducer factor on and off.
Prerequisites for this command
●
[SENSe:]CORRection:TRANsducer<td>:SELect
).
Suffix:
<td>
.
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
OFF | 0
Example:
//Turn on primary transducer
CORR:TRAN1:SEL 'HE200A-20-200.pritrd'
CORR:TRAN1 ON
//Turn on secondary transducer
CORR:TRAN2:SEL 'PreAmp.sectrd'
CORR:TRAN2 ON
Manual operation:
See
See
UNIT<n>:POWer
<Unit>
This command selects the unit displayed on the y-axis.
Suffix:
<n>
.
irrelevant
Remote Commands of the Spectrum Application