6.9.2 Local Users Settings
Here you may define the general settings for the
local users.
Status –
Enable
or Disable.
If the local users are not Enabled, they will register, but they won’t be able to be called.
Prefix
– a prefix that allows calls to be sent to the local users.
All SIP users must start with this prefix. It must be different form the prefix used by the IP PBX.
For instance, when the extensions of the IP PBX are local numbers starting with 2 or 3 (201, 350 etc),
the prefix for SIP local users should be “5”.
Everything that does NOT begin with the digit “5”, will be sent to the PBX.
Depending upon the actual settings of the PBX, a single digit may be enough, or you must specify
several, such as “50”
6.9.3 Local Users Definition
Register the SIP Users who will be able to use the MobiLink IP equipment for calls.
The list is empty at first - click
the button
New
to create a
new (empty) record.
Then use
Edit
to enter the
data for the specific SIP user:
Use Exit to leave the current line , then Save to save the latest settings.
For each user, fill in the local extension number, such as “502”, and the corresponding password,
used together with SIP username for SIP user registration.
The settings for expiration tine and NAT refresh are global (for all users), and they have been.
Notice that each entry in the list of registered SIP users may be individually enabled or disabled, so
there can be a list with several users, out of which only some are currently enabled (active).