MCT88M-IO Operating Manual.doc
2019-03-06
5/20
Fig. 4 LED indicators and function keys
LED indicators
The terminal is equipped with three LED indicators (fig. 4) which are used to signal integral functions and
they can be additionally programmed with other available functions within high level configuration (VISO).
Table 2. LED indicators
Indicator
Colour
Integral functions
LED STATUS
Red/green
Default indicator colour is red. If the terminal is assigned to Alarm
Zone then the LED indicates zone arming (red) or disarming (green).
LED OPEN
Green
LED indicates access granting.
LED SYSTEM
Orange
LED indicates card reading and can signal other system functions
including device malfunction.
Note: Synchronic pulsing of all three LEDs signifies lost communication with MC16 controller.
Buzzer
The terminal is equipped with buzzer which is used to signal integral functions and it can be additionally
programmed with other available functions within high level configuration (VISO).
Inputs
The terminal offers 3 general purpose parametric inputs type NO/NC/EOL/DW and 1 input internally
connected to tamper contact. Input types and electric parameters such as response time and parametric
resistors are defined within low level configuration (RogerVDM). Input functions are assigned within high
level configuration (VISO). Multiple functions can be assigned to the same input at the same time.