Fig. 7 Main window of PR Master software
Fig. 8 CPR32-SE options in PR Master
It is possible to configure some additional options by clicking
CPR32-SE
in the main window of
PR Master software which results in opening the window shown in fig. 8 including summary of
CPR32-NET setup and top menu with following options and commands:
Menu: Settings->Options
In the window opened by means of this option, the administrator can activate/deactivate power
supply tests and internal tests of CPR32-SE unit as well as switch the CPR off and on.
Menu: Settings->Inputs/Outputs
In the window opened by means of this option it is possible to assign functions to CPR32-SE inputs
and outputs. Additionally in case of inputs the administrator can define their NO/NC type and in
case of outputs their normal/inverted type. All input functions can be divided into ON/OFF
monitored and ON monitored. In case of ON/OFF monitored input functions, CPR32-SE detects the
moment of input activation and deactivation. In case of ON monitored input functions, CPR32-NET
detects only their activation, thus it is not relevant how long the input is activated and when it is
deactivated as only the activation triggers certain actions within the system. The list of available
functions is shown in table 4 and table 5.