![Roemheld WM-020-369-10-en BA Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/roemheld/wm-020-369-10-en-ba/wm-020-369-10-en-ba_operating-manual_1476968012.webp)
WM-020-369-10-en
BA SPEEDY classic 2 balance
.doc
STARK Spannsysteme GmbH – Roemergrund 14 - 6830 Rankweil - Austria
Tel.:+43 5522 37400-0 - Fax.:+43 5522 37400-700 - e-mail:
-
www.stark-inc.com
12/16
8.3 Overview of the parts that must be removed for the cleaning:
Procedure for cleaning:
1. Remove locking ring.
2. Carefully lift off retaining ring.
3. Remove ball cage.
4. Remove spring
5. Clean the parts removed incl. housing bore, check for damage and replace if necessary
6. Refit all parts in reverse order.
7. Measure check dimension A (see 8.1) and check function using an individual retractable nipple
Locking ring
Retaining ring with
O-ring
Ball cage with
spring
Piston