QCI0150 REV. 0
Page 12 of 14
Certified 06/04/10
Note: The Rollers [9 &10] have +/-1/8” height adjustment.
No gap between
cam shaft and rod
DOOR PANEL
M5 SOCKET
HEAD CAP SCREW
16
Reinstall the Anti-jumper on the Clamp [8] which
was removed from the Clamp (see step10).
ANTI-JUMPER
STATIONARY PANEL
17
You have the option to use the Vinyl Seal [6] or the Bumpers [14/15].
Optional 1.
Optional 2.
1. For the Vinyl Seal: Cut the Vinyl Seal to size
equal to the Door Panel height minus 1/2”.
Place the Vinyl Seal onto the wall side of
the door panel with vinyl lip facing inside
the shower.
2. For the Bumpers: Place one bumper to
the wall approximately 1/2” from the top
of the Door Panel. Place another bumper to
the wall approximately 1/2” from the bottom of
the Door Panel. (See pictures.)
Be sure that the glass will not hit the
wall directly. Different sized bumpers are included.
Be sure to use the size that allows for the best fit.
VINYL SEAL
BUMPER
Be sure to tighten the set screws
before releasing the door.
View from Inside Shower