72
Problem
Possible
Causes
Suggested
Solutions
Troubleshooting
Motor runs too
fast at set speed
1. MIN SPD and
MAX SPD
settings are too
high.
2. Motor field
connections are
loose (shunt
wound motors
only).
3. Motor is
demagnetized.
4. Tachometer
leads are
reversed.
1. Recalibrate MIN
SPD and MAX
SPD.
2. Check motor
field
connections.
3. Check for proper
braking
technique and
method by which
power is cycled.
4. Check
tachometer
connections.
Содержание RELIANCE ELECTRIC DC3N Series
Страница 83: ...75 Troubleshooting Figure 20 DC3N Block Diagram Block Diagram ...
Страница 90: ...NOTES 82 ...