60
This section shows typical chassis drive connections.
Multiple fixed speeds
Replace the speed adjust potentiometer with series
resistors with a total series resistance of 10K ohms (Figure
14). Add a single pole, multi-position switch with the correct
number of positions for the desired number of fixed speeds.
Application Notes
S3
S2
S1
R1
R2
R4
TOTAL SERIES
RESISTANCE
10K OHMS
R3
Figure 14. Multiple Fixed Speeds
ATTENTION:
The equipment is at line voltage when
AC power is connected. Disconnect and lockout all
ungrounded conductors of the AC power line. Failure to
observe this precaution could result in severe bodily
injury or loss of life.
Содержание RELIANCE ELECTRIC DC3N Series
Страница 83: ...75 Troubleshooting Figure 20 DC3N Block Diagram Block Diagram ...
Страница 90: ...NOTES 82 ...
Страница 91: ...NOTES 83 ...