Installation
Node Controller Installation
92
MagneMotion
Rockwell Automation Publication MMI-UM013B-EN-P - April 2020
Mounting NC-12 Node Controllers
Locate the NC-12 close to the nodes it is responsible for to minimize the length of all wiring.
The node controller can be oriented in any direction that is required. Make sure that the ser-
vice and exclusion zones that are identified in
are maintained. Typical mounting methods for the NC-12 use either
Surface Mounting
The NC-12 can be mounted to a convenient surface by attaching the optional mounting plates
as shown in
. See
Figure 5-6: NC-12 Node Controller Surface Mounting
1.
Align each mounting plate to the NC-12 and secure it to the node controller with two
1/4-20 flat head screws with Loctite 243 per plate. Tighten the screws to 10.1 N•m
[90 in•lb] (four screws total). The maximum thread length into the threaded hole is
7.87 mm [0.310 in].
NOTE:
The Loctite must cure for 2 hours at 22° C [72° F] before using the transport
system.
2.
Orient the node controller with brackets as required and secure it with a minimum of
two M8 screws with M8 split lock washers (one per mounting plate). Tighten the
screws to 26 N•m [230 in•lb]. Make sure that the service and exclusion zones are
maintained.
1/4-20 Flat Head Screw
(4X)
Mounting Plate
(2X)