Installation
Electrical Connections
Node Controller Hardware User Manual
99
Rockwell Automation Publication MMI-UM013B-EN-P - April 2020
Network Connections
The node controllers use communication over an Ethernet network with a host controller for
transport system control and for communication between node controllers. The following pro-
cedure provides the information that is required to make all network communications and
Power over Ethernet connections to the node controllers as shown in
.
NOTE:
The network for the transport system must be a dedicated, separate subnet to mini-
mize any unrelated network traffic.
Figure 5-9: Network Wiring
1.
Connect a Cat 5 network cable for transport system network communications from the
host controller to the Uplink connector on the network switch.
NOTICE
The Ethernet cable that connects a Power over Ethernet switch to the
host controller or other network switches must connect to the Uplink
port. Connecting to other ports can damage the switch or other
devices that are connected to the switch.
Host
Controller
SYNC IT
(optional)
TCP/IP or ENet/IP
EtherNet/IP
Ne
two
rk
Sw
itch
Up
link
Uplink
Up
lin
k
NC LITE
Network
Switch
(PoE)
. . .
SYNC IT
(optional)
. . .
NC-12
NC-S
NC LITE
NC LITE
NC-E
Network
Switch
(No PoE)
Содержание MagneMotion 700-0871-00
Страница 140: ...140 MagneMotion Rockwell Automation Publication MMI UM013B EN P April 2020 This page intentionally left blank ...
Страница 146: ...146 MagneMotion Rockwell Automation Publication MMI UM013B EN P April 2020 This page intentionally left blank ...
Страница 147: ...Node Controller Hardware User Manual 147 Rockwell Automation Publication MMI UM013B EN P April 2020 Notes ...