Standard maintenance and inspection for the motor includes:
Feedback Cable and Motor Feedback Connector: Replacement or Rotation
Feedback connectors are not provided as a replacement part from Rockwell Automation, and it is not recommended to remove or replace them. If the upper shell is
damaged, it can be sourced separately (as an Intercontec M23) and replaced without tampering the feedback wiring and pinout connections.
A feedback connector replacement is also available when the full Encoder Replacement Kit is requested.
See the Knowledgebase article:
Kinetix MMA Frequently Asked Questions
, for additional information.
The motors have an encoder that is connected through a direct coupling. See
for motor
feedback and pin out information.
Rotate Feedback Connector to a New Position
1.
Connect the feedback cable to the motor feedback connector.
The attached cable connection provides a larger area to gain more leverage.
2.
Slowly rotate the motor connector into the desired position.
3.
Disconnect the feedback cable after the motor feedback connector is aligned.
Remove and Install the Feedback Connector
1.
Remove screws that secure the feedback connector to the motor.
2.
Rotate the feedback connector to the necessary position.
3.
Install the feedback connector on the motor. Torque screws to 1.1 N•m (9.74 lb•in).
Verify that no wires were damaged.
4.
Follow
Rotate Feedback Connector to a New Position
if additional adjustments must be made.
•
Rotate Feedback Connector to a New Position
•
Remove and Install the Feedback Connector
•
•
Bearing Inspection and Lubrication
•
•
Shaft Key Removal and Installation
•
Replace, Inspect, and Maintain Blower Filters
•
•
Instructions to Reposition or Replace the Radial Blower Assembly
•
Install the IC17 Clean-air Kit (Includes: Replace Axial Blower)
•
•
•
BURN HAZARD:
Outer surfaces of the motor can reach high temperatures during motor operation. Take
precautions to help prevent accidental contact with hot surfaces. Consider motor surface temperature when you
select motor connectors and cables. Failure to observe these safety procedures could result in personal injury or
damage to equipment.
ATTENTION:
Do not conduct the high-voltage test on the encoder terminal. Always use
shielded cables for the connection with the inverter. To avoid an electric shock hazard,
verify that the voltage has discharged completely before servicing.
IMPORTANT
The MMA-B080
xxx
motor does not allow for rotation of the feedback connector.
For information to change the orientation of the MMA-B080
xxx
, see
Install the Feedback Connector
WARNING:
Risk of equipment damage. When repositioning the feedback connector, take
extra caution not to disconnect the wiring, or to bend, twist, or crimp the wires.
IMPORTANT
The MMA-B080
xxx
motor does not allow for rotation of the feedback connector.
Feedback connectors are designed with 330° of rotational
positioning, but this range may be partially or greatly reduced
because of the blower or motor and blower terminal boxes.