50
Rockwell Automation Publication MM-IN001B-EN-P - February 2022
Kinetix MMA Asynchronous Main Motors Installation Instructions
Blower Replacements
All motors ship with an attached blower housing. Depending on your configuration, the blower housing may have an axial blower, a radial blower, or an IC17 adapter shroud
attached to it. It is possible to replace a blower housing or to convert between blower configurations in some cases.
See
for available conversions and procedure references.
To replace a blower housing with the same configuration, use this list as a reference:
•
Axial blower to axial blower
- see
Install the IC17 Clean-air Kit (Includes: Replace Axial Blower)
•
Radial blower to radial blower
- see
Instructions to Reposition or Replace the Radial Blower Assembly
•
IC17 clean-air to IC17 clean-air
- see
Install the IC17 Clean-air Kit (Includes: Replace Axial Blower)
Blower Conversions
The following are possible blower conversions for axial and radial blowers. To complete
the conversion, use the information that follows.
•
Axial blower or radial blower to IC17 clean-air option
- see
Install the IC17 Clean-air Kit (Includes: Replace Axial Blower)
•
Axial blower to radial blower
- is not an available conversion
•
Radial blower to axial blower
- see
Instructions to Reposition or Replace the Radial Blower Assembly
to
remove the radial blower; see
Install the IC17 Clean-air Kit (Includes: Replace
for guidance to connect the axial blower
•
IC17 clean-air option to axial blower
- see
Install the IC17 Clean-air Kit (Includes: Replace Axial Blower)
guidance to remove cover from blower housing; see
Kit (Includes: Replace Axial Blower)
for guidance to connect the axial
blower
•
IC17 clean-air option to radial blower
- see
Install the IC17 Clean-air Kit (Includes: Replace Axial Blower)
guidance to remove cover from blower housing; see
Reposition or Replace the Radial Blower Assembly,
start at
to install
and connect the radial blower
Do not disconnect the fan or the blower terminals to replace the blower
housing.
IMPORTANT
The radial blower is delivered in the top mounted position. If an alternate orientation is required, only an
experienced technician can install, remove, or reposition the blower. Complete these tasks on a workbench
and not in a mounted position. Replacement of the blower housing requires the torque specifications as
listed in
Shaft Height
180 and 225
only
Shaft Height
100, 132, and 160
only
4X
Installation of IC17 clean-air kit
on a radial blower housing
Blower housing motion direction
Radial blower mating to blower housing
(
orientation may vary)
Feedback connector
removal on a radial
blower
Table 52 - Blower Conversion Options
Possible Conversions
Shaft Height
Initial Option
Converts To
080
100
132
160
180
225
Axial blower
IC17 clean-air
—
Yes
Radial blower
IC17 clean-air
—
No
Yes
Axial blower
Radial blower
No
Radial blower
Axial blower
—
No
(1)
(1)
This conversion requires extension rods that are not available as a spare part. See
for dimensions and specifications.
IC17 clean-air
Axial blower
—
Yes
No
IC17 clean-air
Radial blower
—
No
No
(2)
(2)
This conversion requires the radial blower cover that is not available as a spare part.
Dimensions and specifications can be found in the Knowledgebase article:
, for additional information. See also
.
ATTENTION:
For all blower conversions or
replacements, remove incoming power from the
motor and the blower. Allow time for any stored
energy to discharge.