![Rockwell Automation Allen-Bradley Kinetix MMA-B080 Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-kinetix-mma-b080-series/allen-bradley-kinetix-mma-b080-series_installation-instructions-manual_1475534014.webp)
14
Rockwell Automation Publication MM-IN001B-EN-P - February 2022
Kinetix MMA Asynchronous Main Motors Installation Instructions
Motor Feedback Connector Pinouts
The Kinetix MMA Asynchronous Main Motors are equipped with a SpeedTec DIN feedback connector.
The Kinetix 5700 drive requires the 2198-K57CK-D15M connector kit to attach the motor to the drive. See Universal Feedback Connector Kit Installation Instructions,
publication
, for connector kit specifications.
The Kinetix 7000 drive requires the 2090-K6CK-D15M connector kit to attach the motor to the drive. See Low-profile Connector Kits Installation Instructions, publication
, and EnDat Feedback Module Installation Instructions, publication
for connector kit specifications.
contains connector descriptions for the motor feedback connector. For additional information on the feedback cable, refer
to Kinetix 2090 Feedback Cable for Kinetix Motors with PowerFlex 750-Series Drives, publication
and Feedback Cables, publication
, or Kinetix Rotary and Linear Motion Accessories, publication
Table 5 - Motor Feedback Connector Pinout
Motor Feedback
Connector Pin
Encoder Cat. No.
Signal Description
L2
S1, S2, M1, M2
S3, M3
S4, M4
VFx60
SFx60,
SFx60 SIL 2
ECN413, ENQ425
ECN425,
EQN437
1
A+
—
—
—
A quad B: A differential
—
SIN+
SIN+
—
1V p-p sine differential
2
A-
—
—
—
A quad B: A differential signal -
—
SIN-
SIN-
—
1V p-p sine differential signal -
3
B+
—
—
—
A quad B: B differential
—
COS+
COS+
—
1V p-p cosine differential
4
B-
—
—
—
A quad B: B differential signal -
—
COS-
COS-
—
1V p-p cosine differential signal -
5
—
DATA+
DATA+
DATA+
Serial data differential
IM+
—
—
—
Index differential
6
—
DATA-
DATA-
DATA-
Serial data differential signal -
IM-
—
—
—
Index differential signal -
7
—
—
CLK+
CLK+
Serial data clock differential
8
—
—
CLK-
CLK-
Serial data clock differential signal -
9
—
—
—
—
10
—
—
—
—
11
EPWR 9V
EPWR 9V
EPWR 9V
EPWR 9V
9V DC encoder power
12
ECOM
ECOM
ECOM
ECOM
Encoder power common
13
TS+
TS+
TS+
TS+
Thermostat differential
14
TS-
TS-
TS-
TS-
Thermostat differential signal -
15
—
—
—
—
16
PT1
PT1
PT1
PT1
PT1000 differential
17
PT2
PT2
PT2
PT2
PT1000 differential signal -
12
12
3
6
15
15
1
2
4
5
7
8
9
10
10
11
11
13
13
14
14
17
17
16
16
Feedback Connector on Motor