6
Industrial 15" Flat Panel Monitor
Publication 6185-5.1
•
Determine the minimum and maximum ambient humidity for the
monitor by consulting the specification sheets at the back of this
manual. Ensure that the humidity of the ambient air will not exceed
these limits. In very dry environments, static charges build up very
readily. Proper grounding of the equipment through the AC power
cord can help reduce the likelihood of static discharges, which may
cause shocks and damage electronic components.
When properly installed, the 6185-C Flat Panel Monitor is designed to
provide protection against water and dust to NEMA 4 and NEMA 12
standards.
No slides or shelves are required because the 6185-C Flat Panel Monitor
is designed to be supported by the panels in which it is installed.
Figure 1
Generic Panel Mount Diagram
Tools Needed
In addition to the tools required to make the cutout, you will need the
following tools:
•
3/8” Deep Well Socket
•
1/4” Drive Extension - 6” or longer
•
1/4” Drive Ratchet or 1/4” Drive Torque Ratchet
Panel Mounting