Publication 6185-5.1
Symptom
Possible Problem
Action
Color(s) are missing.
Video cable problem
Check for proper video cable installation.
Replace suspected faulty cable.
Fault in monitor
Have monitor serviced.
Screen jitter or noisy video.
Monitor clock phase not properly
adjusted.
Adjust monitor clock phase settings (Page
25).
Video cable problem.
Check for proper video cable installation.
Replace suspected faulty cable.
Electrical noise interference from nearby
equipment.
Check for proper video cable routing and
installation. Reroute cables or replace
suspected faulty cables.
Check host and monitor grounding.
Slight distortion in text or graphics.
Not operating monitor in native resolution.
Change the Expand/Center setting
(Page 26) or change the video source to
1024x768 resolution.
Screen image does not fill the display
area.
Not operating monitor in native resolution.
Change the Expand/Center setting
(Page 26) or change the video source to
1024x768 resolution.
Image has blurry streaks or "ghosting" to
the right of objects on the screen.
Contrast set too high or overdriven video
if full range dimming option installed.
Adjust brightness and contrast settings
(Page 25). Calibrate the video gain (Page
29).
Video cable problem.
Check for proper video cable installation.
Replace suspected faulty cable.