Rockwell Automation Allen Bradley Bulletin 6185-C 15 Скачать руководство пользователя страница 1

Industrial 15" Flat Panel Monitor

(Bulletin 6185-C)

Installation and User Manual

Содержание Allen Bradley Bulletin 6185-C 15

Страница 1: ...Industrial 15 Flat Panel Monitor Bulletin 6185 C Installation and User Manual...

Страница 2: ...lid state equipment all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable In no event will Rockwell Automation be r...

Страница 3: ...to 1024 x 768 120 H 100 V viewing angle NEMA 4 12 or 4X stainless steel panel Touchscreen options AC 85 264V or DC 24V inputs Plug and Play Full range dimming option ATTENTION The equipment described...

Страница 4: ...te Package of mounting hardware AC power cord optional Video cable optional This user manual A 6185 C Flat Panel Monitor with a touchscreen option is shipped with these additional items Supporting sof...

Страница 5: ...ature at the top of an enclosure is much higher than the rest of the enclosure if the air is not circulating Important This monitor is designed to operate at a range of extremes however it is not good...

Страница 6: ...od of static discharges which may cause shocks and damage electronic components When properly installed the 6185 C Flat Panel Monitor is designed to provide protection against water and dust to NEMA 4...

Страница 7: ...tal cuttings do not enter any components that are already installed in the panel Supporting panels should be at least 14 gauge to ensure proper sealing against water and dust and to provide proper sup...

Страница 8: ...8 Industrial 15 Flat Panel Monitor Publication 6185 5 1 Figure 3 Dimensions Side View Figure 4 Dimensions Back View...

Страница 9: ...Units are in mm inches Note Use 10 32 self locking nuts for mounting Figure 5 Panel Mounting Cutout 2 If access to the side of the monitor is not available following installation attach the power and...

Страница 10: ...f the cutout in the panel 5 Tighten all mounting bolts evenly to a torque of 24 inch pounds ATTENTION Mounting nuts must be tightened to a torque of 24 inch pounds to provide panel seal and avoid pote...

Страница 11: ...eo source HD 15 VGA connector Connecting to a host touchscreen control port DE 9 connector optional Connecting to AC power IEC connector or DC power terminal block Note Some connectors on your monitor...

Страница 12: ...to the output of any IBM compatible VGA adapter or other video generator Note You may connect the monitor to video generators that do not conform to VGA standards The main requirement is that the gene...

Страница 13: ...Use the ground terminal of the monitor below the power and T S connectors to establish a chassis to earth ground connection Secure one end of a ground strap to the ground terminal Connect the other e...

Страница 14: ...re one end of a ground strap to the ground terminal Connect the other end of the ground strap to a good earth ground The ground terminal is an M5 screw ATTENTION Chassis ground must be connected for s...

Страница 15: ...eo driver Monitor Type If you are using Windows 95 or Windows 98 and your video card supports it you should enable your workstation to detect Plug Play monitors and select Plug and Play as the monitor...

Страница 16: ...lat Panel Monitor displays up to 256k colors 18 bit color Because most workstations only support 8 bit 16 bit or 24 bit color you must operate the monitor in True Color mode 24 bit color to utilize th...

Страница 17: ...n colors or patterns you may notice noisy video or jitter problems at that time For example if the horizontal or vertical position of the display is not adjusted correctly one edge of the screen image...

Страница 18: ...1 Start the Adjustment Utility 1 Insert the diskette provided with the monitor in the floppy drive of the host computer 2 Start the Flat Panel Monitor Adjustment utility using the instructions on the...

Страница 19: ...step Step 4 Adjust the horizontal size 1 Highlight the Image Position option on the main menu and press the Select button Then highlight the Horizontal Size option and press the Select button 2 Adjus...

Страница 20: ...press the Select button Then highlight the Horizontal Position option and press the Select button 2 Adjust the horizontal screen position so that the white border line is visible on both sides of the...

Страница 21: ...isplay first set the brightness control to the appropriate setting under the lighting conditions in which the monitor will be used Note Allow time for the backlight on the monitor to warm up completel...

Страница 22: ...ast value up to its highest setting The gray bars on the bottom of the screen image change to white 3 Adjust the contrast down until the white bar stays white and the first light gray bar changes back...

Страница 23: ...Indicator A bicolor LED is provided on the front panel to indicate various operating modes The following table describes the functions assigned to the default LED which is a single light that can be g...

Страница 24: ...djust the user interface settings for the monitor 1 Press the Select top pushbutton on the back panel of the monitor to activate the on screen menu 2 Use the Up and Down pushbuttons to highlight the o...

Страница 25: ...ghtness and fine detail rendition The optimum setting may vary slightly with different types of monitors and changes in ambient lighting as well as individual taste Color Balance Adjusts the balance o...

Страница 26: ...the monitor from top to bottom Expand Center With resolutions less than 1024x768 the Expand setting fills the screen using pixel replication The Center setting puts the image in the center of the scre...

Страница 27: ...ay Fields DPSOH N 9 Value Description Vertical Refresh Rate Vertical clock rate in Hz Vertical Polarity Polarity of vertical sync signal Horizontal Refresh Rate Horizontal clock rate in Khz Horizontal...

Страница 28: ...djust the luminance of the monitor are optional Figure 13 Optional Full Range Dimming Control Note The dimming controls are located on the rear of the monitor with the optional stainless steel front p...

Страница 29: ...al Off On Signal Not Received The monitor is not receiving a valid video signal On blinking slowly Off Backlight Off The monitor is still ON but the backlight is powered OFF Hold down both buttons for...

Страница 30: ...inks slowly to indicate that you are in calibration mode 3 Press the right dimmer button to adjust the contrast value to its highest setting The gray bars on the bottom of the screen image change to w...

Страница 31: ...he risk of abrasion allow the screen to stand dry Special care should be taken when cleaning a touchscreen or polycarbonate shield that is installed over the screen Abrasive and certain chemical clean...

Страница 32: ...Video cable problem Check for proper installation of video cable s Refer to installation instructions Replace suspected faulty cable s Fault in video source Test video source by connecting to another...

Страница 33: ...ute cables or replace suspected faulty cables Check host and monitor grounding Slight distortion in text or graphics Not operating monitor in native resolution Change the Expand Center setting Page 26...

Страница 34: ...rnal touch power connections are necessary Software supplied with the touchscreen must be loaded on the host computer to handle communications with the touch controller over the channel Because the to...

Страница 35: ...the touchscreen Ensure that the RS 232 cable is properly installed between the monitor port and the host s COM port The baud rate at which the controller is operating You will need to match the baud r...

Страница 36: ...ublication 6185 5 1 After installing the driver software follow the instructions in the touchscreen documentation Following installation of the touchscreen software and calibration the touchscreen is...

Страница 37: ...e female connector Figure 14 HD 15 Video Connector The following table provides the pin numbers and corresponding pin assignments for the HD 15 video connector with the DDC2B capability Table F Standa...

Страница 38: ...185 C Flat Panel Monitor will wear out The backlights typically last 50 000 hours before they reach 50 of their original intensity or fail Replacement backlights are available from Rockwell Automation...

Страница 39: ...ypical Video Supported Standards 640x480 at 60Hz and 75Hz 800x600 at 60Hz and 75Hz 1024x768 at 60Hz native and 75Hz Video Input Signal RGB analog white level 0 714V above ref Black into 75 Ohms Sync I...

Страница 40: ...VDC IEC 801 2 level 3 Non Operating Electrostatic Discharge 20 0K VDC Operating Shock 10g 1 2 sine 11msec Non Operating Shock 30g 1 2 sine 11msec Operating Vibration 0 006in p p 10 57Hz 1 0g peak 57...

Страница 41: ......

Страница 42: ...ium Bolivia Brazil Bulgaria Canada Chile China People s Republic of Colombia Costa Rica Croatia Cyprus Czech Republic Denmark Dominican Republic Ecuador Egypt El Salvador Finland France Germany Ghana...