THIS FUNCTION WILL ALLOW MULTIPLE UNITS TO BE SET UP EXACTLY THE SAME AS A
PREDETERMINED “MASTER” UNIT
SYNCHRONIZING TWO SOUNDERS (ALL STAGES)
1
Connect Synch cable to
Master and Slave PCB
2
On both units: Set jumper J6
(SYNC) to ON
Set jumper J5 (S/M) on Master
unit to master position (ON)
Set jumper J5 (S/M) on Slave
unit to slave position (OFF)
NOTE: Position of S2 and S4
dip switches and jumper J4
(ME) does not affect synch
operation.
3
Apply power to the Master
unit first
Then apply power to the Slave
unit
Master Unit
Slave Unit
4a
Press action button on the
Master Unit: Synchronisation
will begin
Master Unit
Slave Unit
4b
- - - - Synchronisation
complete
Switch off Power to units
Master Unit
Slave Unit
5
On both units: Reset on
jumper J6 (SYNC) to OFF
Set jumper J5 (S/M) on
both units to Master
position (ON)
Designate one unit as Master
and one unit as Slave