pag. 11
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH
UPON INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE
SHALL EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground.
Make sure the ground where the appliance will be placed is able to support the weight of the device. If not,
you will need a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please
consult a specialist.
2.2 Wall.
Make sure the wall where the appliance will be placed is able to support the weight of the device. If not, you
will need a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult
a specialist.
RECOMMENDED LOAD WORK
(Quality 6.8, concrete 250 kg/cm
2
)
∅
anchorage
(mm)
Minimum embedding H
(mm)
Extraction strength
(kg)
Shear strenght
(kg)
10
50
350
450
TECHNICAL DETAILS
Rawplug
size (mm)
Screw size
(mm)
∅
Bit
(mm)
Min. drill
depth (mm)
Thickness to fix
max. (mm)
Tightening torque
(kg x cm)
10x80
M8x80
10
85
30
150
2.3 Flue liner.
It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside
in observation of the smoke pipe diameter.
The good condition and suitability of this smoke pipe must be certified
by a professional and must also observe the relevant national regulations.
This Flue liner should not be shared
with other devices
(see Table 1.1 Technical specifications).
2.4 Type of appliance.
This fireplace is exempt, so it doesn’t need any revetment.
2.5 Security insulation and security distance.
Any fragile or flammable element, textiles, electronic devices, wood,
wallpaper, glass, chalk paper, etc., must be separated from the device observing the minimum distance described in
Table
1.1 Technical specifications. Special attention should be paid to equipment installed in contact with wood or similar:
we must prevent or avoid the possibility of hot air impacting directly on the wood: in such case, it shall be insulated
accordingly.
2.6 Air supply.
Air should be provided to the room where the appliance is installed. This is especially relevant when
outside air is not used and also when the door is opened for reloading with logs. This entry cannot be less than 225 cm
2.
Also note the simultaneous operation with other ventilation devices and / or heating such as exhaust fans, heat pumps,
etc. In these cases, the extraction must be compensated with a corresponding air entry from outside.
2.7. Changes to the device.
Any intended change to the equipment must be authorized in writing by Manufacturas
Rocal, S.A. We also recommend using only original spare parts or parts recommended by Manufacturas Rocal, S.A.
3.1 Installation process.
To proceed with the installation, follow the steps outlined in Section III of the ANNEXED
document.
WARNING:
The second piece of the deflector plate (part 7 of the section of the document ANNEX) should
only place in case of excess draught, follow the steps to install it: "D.1", "D.2", "D.3", “D.7” and “D.8 ".
2. REQUIREMENTS PRIOR TO INSTALLATION
3. INSTALLATION