pag. 10
1.1 Technical specifications
Parameter
Value
Minimum - Maximum draught
11-13 Pa
Fuel consumption
2,3 kg/h
Smoke mass flow rate
11 g/s
Performance
83 %
Nominal output
7,8 kW
Power range
5 - 9 kW
Average CO concentration at 13% of O2
0,12%
Particle concentration
27 mg/Nm
3
Payload (trial)
2,1 kg
Reload interval period (trial)
50 min
Medium draft (trial)
12 Pa
Net weight
101 kg
Maximum authorized load (fuel)
3,5 kg
Reload height
200 mm
Logs length
300 mm
Minimum flue height
4000 mm
Flue duct
180 mm
Ø Air inlet
100 mm
Front safety distance
1000 mm
Side safety distance
300 mm
Back safety distance
500 mm
Primary register (trial)
5 mm open
Secondary register (trial)
35 mm open
Average temperature of smoke
144º C
Type of combustion
INTERMITTENT
Flue liner
NOT SHARED
Fuel
NATURAL WOOD
Humidity fuel logs
12-20% - two years under cover
Certification year
2016
Certificate No.:
CEE-0001/16-1
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED
document)
1.
Fireplace’s body.
2.
Flue liner connector.
3.
Heat-resistant spray paint for touch-ups.
4.
Body of the ceiling plate.
5.
Heat-resistant glove.
6.
Trim of the ceiling plate.
7.
Upper baffle plate to adjust draught.
8.
Bag with screws and anchors.
9.
Aluminium ring to connect.
10.
The body of the telescopic ceiling plate.
11.
Fixative of the aluminium ring.
12.
Tool for handling registers and opening door.
13.
Metal clamp.
14.
Exterior air inlet cover.
15.
Bag with metallic anchors.
16.
Cleaning cloth.
17.
Envelope with 3 documents: specifications, installation and operation manual, and Guarantee sheet.
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I, page 1.
1. SPECIFICATIONS