The Clean Air Act 1993 and Smoke Control Areas

The Robus Biopel range of boilers listed below has been recommended as suitable for use in smoke
control areas. The recommended fuel for the boiler is 6mm or 8mm diameter wood pellets to EN 14961
Part 2 class A1 wood pellets only.

Robus Biopel 15
Robus Biopel 20
Robus Biopel 30
Robus Biopel 40

Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a
smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any
fixed boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised
fuel" for use within a smoke control area unless it is used in an "exempt" appliance ("exempted" from the
controls which generally apply in the smoke control area).

The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to authorise
smokeless fuels or exempt appliances for use in smoke control areas in England. In Scotland and Wales this
power rests with Ministers in the devolved administrations for those countries. Separate legislation, the
Clean Air (Northern Ireland) Order 1981, applies in Northern Ireland. Therefore it is a requirement that fuels
burnt or obtained for use in smoke control areas have been "authorised" in Regulations and that appliances
used to burn solid fuel in those areas (other than "authorised" fuels) have been exempted by an Order made
and signed by the Secretary of State or Minister in the devolved administrations.

Further

information

on

the

requirements

of

the

Clean

Air

Act

can

be

found

here

http://smokecontrol.defra.gov.uk/

Your local authority is responsible for implementing the Clean Air Act 1993 including designation and 
supervision of smoke control areas and you can contact them for details of Clean Air Act requirements”

Fuel and warranty

The Robus Biopel pellet boilers are designed for use with EN-plus A grade wood pellets only. The use of
substandard fuels will compromise the efficiency, reduce the life span and invalidate the warranty of the
appliance.

What is EN-Plus?

EN-Plus is the European Quality Standard for the manufacture and supply of wood pellets. Manufacturers
and Distributors who have the EN-Plus standard have been certified as meeting the required quality
standards and they are entitled to display the EN-Plus logo and their own unique License Number.

Содержание BIOPEL

Страница 1: ...Biopel Pellet Boiler Installation manual...

Страница 2: ...ibed here in this manual It is recommended to study the menus prior to initial start Save this manual so you always have it available when needed Page 3 Comments on the Manual Page 4 The Clean Air Act...

Страница 3: ...indication of improper draft of the chimney all operation of your system mustceaseimmediately and mustremain so until a solution to thedraftproblem has been resolved Continuing operation may result i...

Страница 4: ......

Страница 5: ...se countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have b...

Страница 6: ...uts as the seal between the boiler and the burner can leak over time 4 Make sure that the burner is horizontal and that all connections are tight Burner description The main parts of the burner are th...

Страница 7: ...ler for burner installation However the opposite flange on the boiler bust be always sealed For example if you choose left flange for burner connection make sure that right flange is properly sealed B...

Страница 8: ...le located on the top of the burner and secure with 2 x burner pipe screws Attach PVC tube on the burner pipe and from the other side on the external auger outlet You can cut the PVC tube if necessary...

Страница 9: ...nt ignition of the boiler and will prolong the life of the igniter The min buffer thermal store capacity should be 10 litres kW output eg 200 litres for Biopel 20 The load valve supplied with the boil...

Страница 10: ...and connection board are pre wired with simple plugs to allow for quick installation When using the Compact type hopper the connection board can be fixed to the sloping wall of the hopper near the bur...

Страница 11: ...is the boiler pump ROOM REGULATOR Room thermostat volt free Other connections for optional accessories are DHW PUMP Used to control a pump or 2 port valve for hot water production KOMPRESSOR Connecti...

Страница 12: ......

Страница 13: ...t is designed to offer the home owner and installer a series of simple menus to give full control of all boiler settings and parameters The controller has 3 levels of PIN protection in order to preven...

Страница 14: ...t the same time o Summer mode sets the burner power to an half value To be specific Feed time max and Feed interval min is reduced to half Cleaning cleaning of the grate during PID modulation work o A...

Страница 15: ...rection correction of fan speed 50 Power factor correction of burner power Changes values in Feeder time max and Feeder interval min in range of 50 Example if you set 30 in Auger correction 30 it mean...

Страница 16: ...at the size in Kw is correct 5 Burner size changes values in Service settings shown below 6 Auger setup Ignition a Feed time for how long pellet auger supplies pellets on the burner grate b Fan speed...

Страница 17: ...d increase fan speed or pellet quantity High pellets Flame is to long If you open top doors flame goes out of the boiler Often red color and black ends Then you should decrease fan speed or pellet qua...

Страница 18: ...for PID regulation is lower which means speed of the fan is decreased in all PID modulation range Power correction Power correction is responsible for changing number of pellets going on the grate You...

Страница 19: ...removing the ash from the chimney flue Never dispose of hot ashes in the trash but let it cool in a metal bucket Hot ashes can re ignite Burner head Remove any ash or cinders from the grate Remove an...

Страница 20: ...perform service Please note that service indicators are only expectations based on experience Components can easily have a longer lifetime than suggested by the service indicator It is recommended to...

Страница 21: ...e correct positioning Burnergrate rests on support ledge Burnergrate upstand at this end Burnergrate correctlypositioned Burnergrate upstand locked in burner Burner grate incorrect positioning Burner...

Страница 22: ...n receipt If the buyer declares that the delivery was inadequate or defective the customer must immediately and without delay make a written claim with Robus Energy Returns are only made by agreement...

Страница 23: ......

Отзывы: