Robus BIOPEL Скачать руководство пользователя страница 22

Warranty

All products purchased from

Robus Energy

are covered by the standard 1 year

warranty. This includes 12 months warranty on the products valid from the date of
receipt. A 2 year warranty is granted with the completion of the

Warranty

Registration

.

Robus Biopel range.

A five year manufacturer’s warranty is available on the boiler vessel only if
installation is done to manufacturer installation instructions.

Note: Electrical Igniters are not covered under the warranty as they are a
wearable part.

The warranty only covers manufacturing and material defects. In case of product
failure of the system when under warranty,

Robus Energy

will replace the spare

part at no charge to the buyer within the first year. Buyer will be responsible for
the installation or replacement of the part thereafter. If

Robus Energy

offers

replacement of the defective part the purchaser shall send the part to

Robus

Energy

for replacement. Guarantee shall be invalid if product failure is due to

circumstances caused by the buyer; either by accident and/or abuse of the
product, poor installation, inadequate cleaning, chimney conditions, as well as
circumstances where

Robus Energy

has no influence. In addition, the warranty is

invalid due to misuse of the burner for example using fuel that is not approved by

Robus Energy.

The warranty does not cover parts such as the electrical igniter. The

buyer is obligated to check the goods immediately upon receipt. If the buyer
declares that the delivery was inadequate or defective, the customer must
immediately and without delay make a written claim with

Robus Energy

. Returns

are only made by agreement with

Robus Energy

. To the extent that

Robus Energy

is liable to the purchaser,

Robus Energy’s

liability is limited only to direct loss and

not to damages incurred by connected equipment and/or indirect damage, loss of
earnings, operating losses, connection costs, etc.

Responsibilities:

Robus Energy

assumes no responsibility as a result of the

purchaser's legal relations with third parties. All orders are accepted subject to
force majeure, including war, civil unrest, natural disasters, strikes and lockouts,
failing supplies of raw materials, fire, damage to

Robus Energy

or its supplier

network, lack of transport opportunities, import / export prohibitions or any other
event which prevents or restricts

Robus Energy’s

ability to deliver.

Robus Energy

has in cases of force majeure, the right to cancel the transaction or any part
thereof, or to deliver the agreed product as soon as the obstacle to normal delivery
has lapsed. In cases of force majeure,

Robus Energy

will not be held responsible for

any losses incurred by the purchaser due to non-delivery.

Robus Energy

will not be

held responsible for any changes and/or faults related to price changes, sold out
items or changes to specifications in the product manual. It is the buyer's
responsibility to register the equipment to the appropriate authorities. If any
disputes arise between the authorities and the purchaser,

Robus Energy

will be

held harmless from any claims or disputes.

Содержание BIOPEL

Страница 1: ...Biopel Pellet Boiler Installation manual...

Страница 2: ...ibed here in this manual It is recommended to study the menus prior to initial start Save this manual so you always have it available when needed Page 3 Comments on the Manual Page 4 The Clean Air Act...

Страница 3: ...indication of improper draft of the chimney all operation of your system mustceaseimmediately and mustremain so until a solution to thedraftproblem has been resolved Continuing operation may result i...

Страница 4: ......

Страница 5: ...se countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have b...

Страница 6: ...uts as the seal between the boiler and the burner can leak over time 4 Make sure that the burner is horizontal and that all connections are tight Burner description The main parts of the burner are th...

Страница 7: ...ler for burner installation However the opposite flange on the boiler bust be always sealed For example if you choose left flange for burner connection make sure that right flange is properly sealed B...

Страница 8: ...le located on the top of the burner and secure with 2 x burner pipe screws Attach PVC tube on the burner pipe and from the other side on the external auger outlet You can cut the PVC tube if necessary...

Страница 9: ...nt ignition of the boiler and will prolong the life of the igniter The min buffer thermal store capacity should be 10 litres kW output eg 200 litres for Biopel 20 The load valve supplied with the boil...

Страница 10: ...and connection board are pre wired with simple plugs to allow for quick installation When using the Compact type hopper the connection board can be fixed to the sloping wall of the hopper near the bur...

Страница 11: ...is the boiler pump ROOM REGULATOR Room thermostat volt free Other connections for optional accessories are DHW PUMP Used to control a pump or 2 port valve for hot water production KOMPRESSOR Connecti...

Страница 12: ......

Страница 13: ...t is designed to offer the home owner and installer a series of simple menus to give full control of all boiler settings and parameters The controller has 3 levels of PIN protection in order to preven...

Страница 14: ...t the same time o Summer mode sets the burner power to an half value To be specific Feed time max and Feed interval min is reduced to half Cleaning cleaning of the grate during PID modulation work o A...

Страница 15: ...rection correction of fan speed 50 Power factor correction of burner power Changes values in Feeder time max and Feeder interval min in range of 50 Example if you set 30 in Auger correction 30 it mean...

Страница 16: ...at the size in Kw is correct 5 Burner size changes values in Service settings shown below 6 Auger setup Ignition a Feed time for how long pellet auger supplies pellets on the burner grate b Fan speed...

Страница 17: ...d increase fan speed or pellet quantity High pellets Flame is to long If you open top doors flame goes out of the boiler Often red color and black ends Then you should decrease fan speed or pellet qua...

Страница 18: ...for PID regulation is lower which means speed of the fan is decreased in all PID modulation range Power correction Power correction is responsible for changing number of pellets going on the grate You...

Страница 19: ...removing the ash from the chimney flue Never dispose of hot ashes in the trash but let it cool in a metal bucket Hot ashes can re ignite Burner head Remove any ash or cinders from the grate Remove an...

Страница 20: ...perform service Please note that service indicators are only expectations based on experience Components can easily have a longer lifetime than suggested by the service indicator It is recommended to...

Страница 21: ...e correct positioning Burnergrate rests on support ledge Burnergrate upstand at this end Burnergrate correctlypositioned Burnergrate upstand locked in burner Burner grate incorrect positioning Burner...

Страница 22: ...n receipt If the buyer declares that the delivery was inadequate or defective the customer must immediately and without delay make a written claim with Robus Energy Returns are only made by agreement...

Страница 23: ......

Отзывы: