ROBOVENT • CLARION SERIES OWNER’S MANUAL
11
SECTION 400
Installation
(continued)
After securing the Collector, fit an angle flange to the Clarion unit’s
intake, then connect a short length of flexible duct or a section of
rigid metal duct from the Collector inlet to the angle flange that was
installed on the top of the CNC (see Figure 6).
Connecting Drain Hoses:
The Clarion Series Collectors has 2 or 3 drain outlets located on the
underside of the Collector. Connect the provided clear plastic tubing
to each drain. The tubing can be installed in two ways. It can be loop
connected (see Figure 7) or submerged into the reservoir tank. Either
installation will work to create a fluid air trap so your Collector will
drain properly. This is essential otherwise air or coolant can be drawn
backwards through these tubes into the Collector, because of the
negative vacuum pressure inside the Collector. Failure to properly
install the drain hoses will greatly reduce efficiency of the Collector as
it will prevent coolant from draining down the tubes, and the unit will
not function properly.
Each tube must have a loop (as shown) that will create the fluid air
trap to isolate the internal reservoir. Secure the loop with a zip-tie and
FMC-1100 on CNC OpMan
DETAIL A
SCALE 1 / 5
A
FIGURE 7
place the open end over an area that will allow the coolant to drain back into the machine or the coolant sump. Do
not submerge the open end into the coolant as this will form a double trap.
The other option is to set up a submerged system that does not require a loop set-up. If this installation is preferred
make sure the open end of each tube is totally submerged into the machine’s coolant sump or reservoir. If the
reservoir runs low or below the tubing you will lose the fluid air trap. The tubing must be submerged at least 12” into
the reservoir.
Electrical Hook-up:
The Oil Mist Series requires a 3 phase, 460 volt electrical feed (230 Volt and 110 Volt available as options on certain
models. Verify your particular model by looking at the rating tag on the Collector or on the relevant Specification
Sheet). Amperage requirements for the motor can be found on the Specification Sheet for the particular Clarion
collector. Electrical connections should only be done by a licensed electrician and accordance with NEC and all
applicable local codes. (See Appendix for electrical schematic.)
The exact electrical connection will be determined by what model unit is ordered.
Содержание CLARION CFX Series
Страница 2: ......
Страница 13: ...ROBOVENT CLARION SERIES OWNER S MANUAL 13 SECTION 600 Motor Greasing Guide ...
Страница 22: ...22 ROBOVENT CLARION SERIES OWNER S MANUAL ...
Страница 24: ......
Страница 25: ...APPENDIX A GeneralWiring Diagrams ...
Страница 26: ...A 1 ROBOVENT CLARION SERIES OWNER S MANUAL APPENDIX A GeneralWiringDiagram ...
Страница 27: ...APPENDIX B HEPA Filters Installation Maintenance ...
Страница 32: ......
Страница 33: ...APPENDIX C Parts List ...
Страница 37: ......