3-Finger Adaptive Robot Gripper Instruction Manual
7.4 Finger Pad Replacement
Maintenance interval
Tools you need
Parts you need
1 M cycles or when wear is visible
l
2.0mm precision flat head screwdriver.
l
Dry tissue or towel.
l
Philips screwdriver.
(To change pads on all 3 fingers)
l
Three (3) Robotiq 3-Finger Adaptive Robot
Gripper Finger Median Pads.
l
Three (3) Robotiq 3-Finger Adaptive Robot
Gripper Finger Proximal Pads.
l
Twelve (12) 4-40 X 1/4 Flat Head Machine
Screws (Philips, zinc coated).
See Spare Parts, Kits and Accessories section to order Robotiq 3-Finger Adaptive Robot Gripper replacement parts.
Note
Always turn off robot and Gripper power supply before performing maintenance operations on the Gripper.
Procedure
1.
Remove the Gripper from the robot following schematics in section 3.3 Mechanical connections.
2.
Clean the Gripper following instructions in 7.1 Gripper cleaning.
3.
Remove the Finger Pads as described in section 6.3.1 Finger Pad.
4.
Clean the fingers of any debris or residue.
5.
Fix the new Finger Pads (custom or standard) as instructed in section 6.3.1 Finger Pad.