ADJUSTING THE MIRROR

Re-adjusting the mechanical stop on the Roboscan PRO 1220-mirror adaptor is required if
the pan or tilt motor occasionally loses steps, leaving the mirror incorrectly positioned after
a reset is performed. This error occurs when the recoil of the mechanical reset bounces the
mirror and bracket a whole pan or tilt motor step. (N.B. A controller is necessary to make
this adjustment)

Reset the Roboscan PRO 1220

Figure 3

The pan motor adjustment:

1 Use the trackball to move the cursor

to

the

upper-left

corner

of

the

movement-grid on the 2032-controller
until the screw (A1) in figure 3 is
positioned at the upper mechanical-
stop (A2).

2 Release the lock-nut on the adjusting

screw (A1).

3 Turn the screw (A1) clockwise about

1/2 - 1 turn, hereby increasing the
distance between the head of the
screw and the mechanical-stop (A2).

4 Tighten the lock-nut on screw (A1).
5 Reset the Roboscan PRO 1220 a

number

of

times

to

check

the

accuracy of the new reset position.

6 Use

the

trackball

on

the

2032

controller to move the mirror through
all

other

positions,

check

that

adjustment screw (B1) does NOT
touch the mechanical stop (B2) during
these steps. If it does then adjust
screw (B1) accordingly.

The Tilt-motor adjustment:

1 Use the trackball to move the cursor to the upper-left corner of the movement-grid on

the 2032-controller until the top mechanical-stop (C1) in figure 3 is positioned at the
edge of the mirror bracket (C2)

2 Loosen the two allen-screws (E) holding the axle of the motor while observing that the

motor does not slide vertically from its current position.

3 Carefully turn the motor and mirror clockwise (observe that the motor axle does NOT

turn.) until there is a distance of about 1/2 to 1 mm between the edge of the mirror
bracket (C2) and the top mechanical-stop (C1).

4 Tighten the allen-screws.
5 Use the trackball on the 2032-controller to move the mirror through all outer positions,

check that bottom mechanical-stop (D1) does NOT touch the edge of the mirror
bracket (D2) during these steps. If it does then re-adjust as described making the
distance between (C2) and (C1) even smaller.

Содержание PRO 1220

Страница 1: ...Roboscan PRO 1220 users guide...

Страница 2: ...OLLER 5 NOTES ON HOW TO TURN ON THE PRO 1220 LAMP FROM YOUR CONTROLLER 6 SEQUENTIAL SOFTSTART OF THE MSR 1200 LAMP 6 LAMP ADJUSTMENT 7 ADJUSTING THE MIRROR 8 ADJUSTING THE PAN TILT DAMPERS 9 REGENERAT...

Страница 3: ...ti layer coated giving 35 higher light output than previous versions Top cover with snap lock and safety wire provides instant access to the unit Efficient fan cooling Can be controlled by the 2032 co...

Страница 4: ...the screws marked No 1 see Figure 1 one quarter turn and lift out the lamp holder plate Hold the lamp by the ceramic parts taking care not to touch the glass parts Push the lamp firmly into the lamp h...

Страница 5: ...with the controller they should be connected together with XLR XLR cables The order is not important use an order which gives the easiest and shortest cable routing The last unit on the link should b...

Страница 6: ...ntroller you will need the following instructions After booting up the controller you will find yourself at the Main Menu click on the field marked Sequence Select the units that you wish to turn on o...

Страница 7: ...the cover is removed which means that while you are adjusting the position of the lamp this switch needs to be fixed down constantly A Point the beam at a flat surface Using the controller set the Rob...

Страница 8: ...e new reset position 6 Use the trackball on the 2032 controller to move the mirror through all other positions check that adjustment screw B1 does NOT touch the mechanical stop B2 during these steps I...

Страница 9: ...t or extreme top to extreme bottom for Tilt adjustment Whilst the mirror is moving watch the beam movement to ensure that it is smooth Tighten the dampers F1 and F2 until the smoothness of the mirror...

Страница 10: ...secure the cover over the terminal connections located at the mirror end of the unit Locate the Brown wire marked with a V If this wire is connected to the 120V terminal then move it to the 100V termi...

Страница 11: ...will see that there are Three PCB Connectors connecting the module to a wiring loom remove these Three connectors taking care to note the location and direction of each one On each side of every modul...

Страница 12: ...ction A and B use the same settings Test Demo Demo random 1 Demo random 2 Mechanical stop For service use Adjustment For Service use Led chase For Service use All switches set to OFF position 2 6 2 3...

Страница 13: ...TECHNICAL SPECIFICATIONS Roboscan PRO 1220 Dimensions Length Width Height 1090 mm 316 mm 290 mm Weight 49 0 Kg Fuse 20 AT 6 3 X 32 mm Power consumption 1550 W Lamp Philips 1200 W MSR...

Отзывы: