REGENERATING BAD LAMPS

It can occur that, after a period of time, problems can develop with discharge lamps when
they have been running with too low voltage. The low voltage causes the lamp to burn with
a blue arc inside and also causes the lamp to become black on the inside. When the lamp
is black on the inside the lamp will refuse to start at normal voltage.
In this situation it is possible to regenerate the lamp and so continue its expected life, to do
this you should follow the instructions below :

Unscrew the 4 finger screws which secure the cover over the terminal connections located
at the mirror end of the unit. Locate the Brown wire marked with a V. If this wire is
connected to the 120V terminal then move it to the 100V terminal. If the brown wire is
connected to the 230V or the 250V terminal then move it to the 215V terminal.

Switch on the power to the unit and if the lamp starts let it burn at this voltage for
approximately 5 minutes and then switch off again. The lamp will now be clear on the inside
and ready to re-use at the normal voltage. Re-connect the Brown wire to the terminal where
it was before and start the unit as normal.

If the lamp refused to start, please contact your local Martin Dealer and let him regenerate
the lamp in a special fixture.

Содержание PRO 1220

Страница 1: ...Roboscan PRO 1220 users guide...

Страница 2: ...OLLER 5 NOTES ON HOW TO TURN ON THE PRO 1220 LAMP FROM YOUR CONTROLLER 6 SEQUENTIAL SOFTSTART OF THE MSR 1200 LAMP 6 LAMP ADJUSTMENT 7 ADJUSTING THE MIRROR 8 ADJUSTING THE PAN TILT DAMPERS 9 REGENERAT...

Страница 3: ...ti layer coated giving 35 higher light output than previous versions Top cover with snap lock and safety wire provides instant access to the unit Efficient fan cooling Can be controlled by the 2032 co...

Страница 4: ...the screws marked No 1 see Figure 1 one quarter turn and lift out the lamp holder plate Hold the lamp by the ceramic parts taking care not to touch the glass parts Push the lamp firmly into the lamp h...

Страница 5: ...with the controller they should be connected together with XLR XLR cables The order is not important use an order which gives the easiest and shortest cable routing The last unit on the link should b...

Страница 6: ...ntroller you will need the following instructions After booting up the controller you will find yourself at the Main Menu click on the field marked Sequence Select the units that you wish to turn on o...

Страница 7: ...the cover is removed which means that while you are adjusting the position of the lamp this switch needs to be fixed down constantly A Point the beam at a flat surface Using the controller set the Rob...

Страница 8: ...e new reset position 6 Use the trackball on the 2032 controller to move the mirror through all other positions check that adjustment screw B1 does NOT touch the mechanical stop B2 during these steps I...

Страница 9: ...t or extreme top to extreme bottom for Tilt adjustment Whilst the mirror is moving watch the beam movement to ensure that it is smooth Tighten the dampers F1 and F2 until the smoothness of the mirror...

Страница 10: ...secure the cover over the terminal connections located at the mirror end of the unit Locate the Brown wire marked with a V If this wire is connected to the 120V terminal then move it to the 100V termi...

Страница 11: ...will see that there are Three PCB Connectors connecting the module to a wiring loom remove these Three connectors taking care to note the location and direction of each one On each side of every modul...

Страница 12: ...ction A and B use the same settings Test Demo Demo random 1 Demo random 2 Mechanical stop For service use Adjustment For Service use Led chase For Service use All switches set to OFF position 2 6 2 3...

Страница 13: ...TECHNICAL SPECIFICATIONS Roboscan PRO 1220 Dimensions Length Width Height 1090 mm 316 mm 290 mm Weight 49 0 Kg Fuse 20 AT 6 3 X 32 mm Power consumption 1550 W Lamp Philips 1200 W MSR...

Отзывы: