HOW TO INSTALL THE ROBOSCAN PRO 1220
IMPORTANT !
BEFORE ATTEMPTING ANY OF THE FOLLOWING PLEASE ENSURE THAT THE UNIT
IS
DISCONNECTED FROM ANY MAINS AC POWER
To install the lamp inside the PRO 1220 you must first locate the rear end plate, at the
end of the unit where the fans are located. On this end-plate you will see a black
mounted lever. Press and then release the small section of the lever on the left hand
side. The lever will then open. Now you are able to slide the whole top cover towards
the mirror and then remove it upwards, being careful not to damage the mirror,
revealing the inside of the unit. Locate the lamp holder which is placed at the fan end
of the unit.
Turn the screws marked No.1 (see Figure 1) one quarter turn and lift out the lamp
holder plate. Hold the lamp by the ceramic parts, taking care not to touch the glass
parts. Push the lamp firmly into the lamp-holder, carefully replace the lamp-holder plate
and tighten screws marked No.1.
To replace the top cover simply place it back onto the unit over the mirror and then
slide it towards the fan end of the unit. It is necessary to replace the cover in this way
as there are some securing points along the side of the unit which have to slide into
one another to secure the cover correctly. When the cover is in place simply press the
large section of the black lever until it clicks and locks into position.
Remove the transport fixture from the mirror.
IMPORTANT !
IF YOU DO TOUCH THE GLASS PART OF THE LAMP WITH YOUR FINGERS YOU
MUST
CLEAN IT THOROUGHLY WITH ALCOHOL BEFORE USE