Roboscan PRO 1220 Скачать руководство пользователя страница 4

HOW TO INSTALL THE ROBOSCAN PRO 1220

IMPORTANT !

BEFORE ATTEMPTING ANY OF THE FOLLOWING PLEASE ENSURE THAT THE UNIT

IS

DISCONNECTED FROM ANY MAINS AC POWER

To install the lamp inside the PRO 1220 you must first locate the rear end plate, at the
end of the unit where the fans are located. On this end-plate you will see a black
mounted lever. Press and then release the small section of the lever on the left hand
side. The lever will then open. Now you are able to slide the whole top cover towards
the mirror and then remove it upwards, being careful not to damage the mirror,
revealing the inside of the unit. Locate the lamp holder which is placed at the fan end
of the unit.

Turn the screws marked No.1 (see Figure 1) one quarter turn and lift out the lamp
holder plate. Hold the lamp by the ceramic parts, taking care not to touch the glass
parts. Push the lamp firmly into the lamp-holder, carefully replace the lamp-holder plate
and tighten screws marked No.1.

To replace the top cover simply place it back onto the unit over the mirror and then
slide it towards the fan end of the unit. It is necessary to replace the cover in this way
as there are some securing points along the side of the unit which have to slide into
one another to secure the cover correctly. When the cover is in place simply press the
large section of the black lever until it clicks and locks into position.

Remove the transport fixture from the mirror.

IMPORTANT !

IF YOU DO TOUCH THE GLASS PART OF THE LAMP WITH YOUR FINGERS YOU

MUST

CLEAN IT THOROUGHLY WITH ALCOHOL BEFORE USE

Figure 1

Содержание PRO 1220

Страница 1: ...Roboscan PRO 1220 users guide...

Страница 2: ...OLLER 5 NOTES ON HOW TO TURN ON THE PRO 1220 LAMP FROM YOUR CONTROLLER 6 SEQUENTIAL SOFTSTART OF THE MSR 1200 LAMP 6 LAMP ADJUSTMENT 7 ADJUSTING THE MIRROR 8 ADJUSTING THE PAN TILT DAMPERS 9 REGENERAT...

Страница 3: ...ti layer coated giving 35 higher light output than previous versions Top cover with snap lock and safety wire provides instant access to the unit Efficient fan cooling Can be controlled by the 2032 co...

Страница 4: ...the screws marked No 1 see Figure 1 one quarter turn and lift out the lamp holder plate Hold the lamp by the ceramic parts taking care not to touch the glass parts Push the lamp firmly into the lamp h...

Страница 5: ...with the controller they should be connected together with XLR XLR cables The order is not important use an order which gives the easiest and shortest cable routing The last unit on the link should b...

Страница 6: ...ntroller you will need the following instructions After booting up the controller you will find yourself at the Main Menu click on the field marked Sequence Select the units that you wish to turn on o...

Страница 7: ...the cover is removed which means that while you are adjusting the position of the lamp this switch needs to be fixed down constantly A Point the beam at a flat surface Using the controller set the Rob...

Страница 8: ...e new reset position 6 Use the trackball on the 2032 controller to move the mirror through all other positions check that adjustment screw B1 does NOT touch the mechanical stop B2 during these steps I...

Страница 9: ...t or extreme top to extreme bottom for Tilt adjustment Whilst the mirror is moving watch the beam movement to ensure that it is smooth Tighten the dampers F1 and F2 until the smoothness of the mirror...

Страница 10: ...secure the cover over the terminal connections located at the mirror end of the unit Locate the Brown wire marked with a V If this wire is connected to the 120V terminal then move it to the 100V termi...

Страница 11: ...will see that there are Three PCB Connectors connecting the module to a wiring loom remove these Three connectors taking care to note the location and direction of each one On each side of every modul...

Страница 12: ...ction A and B use the same settings Test Demo Demo random 1 Demo random 2 Mechanical stop For service use Adjustment For Service use Led chase For Service use All switches set to OFF position 2 6 2 3...

Страница 13: ...TECHNICAL SPECIFICATIONS Roboscan PRO 1220 Dimensions Length Width Height 1090 mm 316 mm 290 mm Weight 49 0 Kg Fuse 20 AT 6 3 X 32 mm Power consumption 1550 W Lamp Philips 1200 W MSR...

Отзывы: