![Roboscan PRO 1220 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/roboscan/pro-1220/pro-1220_user-manual_1471052012.webp)
DIP SWITCH SETTINGS FOR THE ROBOSCAN PRO 1220
Address settings for RoboScan PRO 1220
Unit no.
Section A
Section B
Unit no.
Section A
Section B
1
2
3
4
5
6
7
8
1
1,2
1,3
1,2,3
1,4
1,2,4
1,3,4
1,2,3,4
2
3
2,3
4
2,4
3,4
2,3,4
5
9
10
11
12
13
14
15
16
1,5
1,2,5
1,3,5
1,2,3,5
1,4,5
1,2,4,5
1,3,4,5
1,2,3,4,5
2,5
3,5
2,3,5
4,5
2,4,5
3,4,5
2,3,4,5
6
Sequence settings for RoboScan PRO 1220
Description
Section A and B use the same settings
Test
Demo
Demo random 1
Demo random 2
Mechanical stop (For service use)
Adjustment (For Service use)
Led chase (For Service use)
All switches set to OFF position
2,6
2,3,6
4,6
1,3,4,5,6
3,4,5,6
2,4,5,6
This page shows the different address and sequence settings for the DIP switches in section
A and B on the RoboScan PRO 1220.
The above settings refer to the pin(s) on the DIP switch which are set to the ON position.