TECHNICAL INFORMATION
ENG
3.4. DESCRIPTION OF ELECTRICAL DEVICES
The figure shows the position of the devices on the machine.
1.
Photocell (B1)
It detects product presence on the infeed conveyor.
2.
Photocell (B2)
It detects product presence on the outfeed conveyor.
3.
Timing sensor (SQ3)
It detects the rotary ring in the start cycle position (machine set up).
4.
Microswitch (SQ1)
The machine stops when the guard is opened.
5.
Electric motor
It activates the rotary ring.
6.
Electric motor
It activates the infeed conveyor.
7.
Electric motor
It activates the outfeed conveyor.
8.
Sensor
It detects the clamp in the “back” position.
Important
For further details see the wiring diagram.