Assembling and Installation
Unpack the machine carefully. Check the delivery set. Remove protective
film from all surfaces. Put at the dedicated place, lock all four swivel
casters.
2.1
Power requirements
Power outlet must have grounding contact!
Presence of grounding connection must be checked
on regular basis!
If supply cord damaged, it must be replaced by
manufacturer, service agent, or qualified persons
in order to avoid hazard!
Connections must be done by qualified electrician
ONLY!
For 400 V, 50 Hz service use IEC 60309 3P+N+PE
32 A plug:
For 208–240 V, 60 Hz service use NEMA 15-60P plug:
Equipotential bonding wire (up to 10 sq.mm) shall be
connected to screw terminal marked with IEC 5021
sign:
2.2
Ambient conditions and vent requirements
The equipment must be operated at the ambient temperature from +5
◦
C
to +40
◦
C (+41
◦
F to +104
◦
F) and relative humidity not more than 45%
at 40
◦
C (104
◦
F). The temperature decreasing related to RH increasing,
6