dEF (reset to default)
List parameters until you see
dEF
on the dis-
play, press and hold COOLING button and press START button once. All
parameters, except basic turbine speed will be reset to its default values,
and the machine will be shut off. NOTE: only available if the turbine is
not running.
The new value is saved once changed. If the turbine is stopped, press
EMERGENCY STOP button,
or
press START button once
dEF
appears
on the display. If the turbine isn’t stopped (the machine is in either heat-
ing, or popping, or cooling stages), then press and hold two temperature
adjustment push buttons for 5 seconds to exit.
Param
Description
Default
Min
Max
Inc
tP
Time_Popping
180*
150
300
30
Fr
Feeder_RPM
160*
100
350
10
tF
Time_Feeder
10
10
30
5
tb
Time_Boost
10
10
30
5
tH
Time_Heating
40
10
60
5
Sr
Sifter_RPM
95
10
95
5
FP
Freq_Popping
10
10
15
1
Fb
Freq_Boost
20
15
30
1
Cn
Cnt_Pop
15
3
30
3
Pt
Temp_P
450*
100
950
50
It
Temp_I
150*
100
950
50
dT
Temp_d
40
0
90
10
tE
Temp_Preheat
60
0
90
30
dEF
Reset to default –
–
–
–
* — three digit values are displayed without last zero digit, for example:
tP18
reading means that
tP
is set at 180.
21