SECTION 3: C
LEARANCES
TO
C
OMBUSTIBLES
7
NOTE:
1. All dimensions are from the s
u
rfaces of all t
u
bes, co
u
plings and elbo
w
s.
2. Clearances B, C and D can be red
u
ced by 50% after 25' (7.5 m) of t
u
bing do
w
nstream
from
w
here the b
u
rner and b
u
rner t
u
be connect.
FIGURE 7: U-TUBE, LEVEL REFLECTOR
(inches)
(centimeters)
Model
A
B
C
D
A
B
C
D
HED-40
- UNAPPROVED -
- UNAPPROVED -
HED-60
6
35
63
30
16
89
161
77
HED-80
6
38
69
37
16
97
176
94
HED-100
6
40
76
39
16
102
194
100
HED-125
6
46
79
43
16
117
201
110
HED-150
6
50
84
47
16
127
214
120
HED-175
8
54
87
51
21
138
221
130
FIGURE
8
: U-TUBE, 45
°
(inches)
(centimeters)
Model
A
B
C
D
A
B
C
D
HED-40
- UNAPPROVED -
- UNAPPROVED -
HED-60
8
8
60
42
21
21
153
107
HED-80
8
8
66
46
21
21
168
117
HED-100
8
8
74
52
21
21
188
133
HED-125
8
8
78
61
21
21
199
155
HED-150
8
8
84
66
21
21
214
168
HED-175
8
8
85
70
21
21
216
178
D
B
A
C
FIGURE 9: U-TUBE, OPPOSITE 45
°
REFLECTOR
(inches)
(centimeters)
Model
A
B
C
D
A
B
C
D
HED-40
- UNAPPROVED -
- UNAPPROVED -
HED-60
8
54
60
22
21
138
153
56
HED-80
8
60
66
22
21
153
168
56
HED-100
10
64
74
22
26
163
188
56
HED-125
10
70
78
22
26
178
199
56
HED-150
12
74
84
22
31
188
214
56
HED-175
12
76
85
22
31
194
216
56
Содержание COMPLETE HED Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 24: ...HED SERIES INSTALLATION OPERATION AND SERVICE MANUAL 18 FIGURE 17 Linear Heater Assembly Overview ...
Страница 25: ...SECTION 6 HEATER INSTALLATION 19 FIGURE 18 Linear Heater Layout Overview ...
Страница 35: ...SECTION 7 OPTIONAL HEATER ACCESSORIES 29 FIGURE 21 U Tube Heater Layout Overview ...
Страница 62: ...HED SERIES INSTALLATION OPERATION AND SERVICE MANUAL 56 ...
Страница 63: ...SECTION12 TROUBLESHOOTING 57 12 2 Manifold Gas Pressure Setting ...
Страница 68: ......
Страница 69: ...2017 ...
Страница 70: ......
Страница 71: ......
Страница 72: ......