EN
- 25 -
6 Troubleshooting
SYMPTOMS
POSSIBLE REASONS
SOLUTIONS
Display OFF
Display
switches on
when button
is pressed
Display auto off mode
activated
Fixture tools
menu
D
isplay mode
(see
4.7.2)
Display still
off when
button is
pressed
No power
Check :
power supply
thermal protection
the power supply connector must be
properly interlocked
System and data display
switched on in red
Problem with the DMX512
received signal and/or system
default
– details available in
4/6 Fixture Tools
menu
Failure details are available in
4/6 Fixture
Tools
menu
The unit
cannot
controlled
via DMX
(inactivated
wireless
DMX)
Data display
switched
on in red
DMX protocol problem
Check data signal
The received data
protocol can be
checked in the
Fixture tools
menu
Data cabling problem
Check cabling and data
connectors
Data display
switched
on in green
DMX address
Check the DMX
address
The strobe is active and the
channel value is void
The value must be 255 (100%) in order to
have the light intensity dimmed
When using several units,
dimming are not
synchronized
Different
Resolution
All the units must have the same resolution
(See 4.7.2 Fixture param.
Resolution
)
Different
smoothing
All the units must have the same smoothing
(See 4.7.2 Fixture param menu
Smoothing
)
Different
Dimming curve
All the units must have the same dimming
curve (See 4.7.2 Fixture param menu
Light
Curve
)
Light switches on when
powered on
Manual value is operating
when DMX is not connected
Local values
must be at zero
Light switches on when
using the control board
Use of the Focus mode
See
4.7.2
Strobe function doesn’t work
Strobe function inactive
Strobe must be activated in Fixture param.
menu
Strobe Control
Strobe function active
Control channel must be higher than 0
Содержание 340CLF CW
Страница 19: ...FR 18 4 6 Contr le de la forme du faisceau 4 6 1 Etendue 4 6 2 Contr le Exemples Ouvert Triangle Carr Ligne...
Страница 41: ...EN 15 4 3 2 Control Manually operated 4 3 3 Control Pole operated Colour Function Yellow Focus...
Страница 43: ...EN 17 4 5 Colour One fixed colour Any standard colour effect filter gel See 3 3 1 for installation Size...
Страница 44: ...EN 18 4 6 Beam shaping with barndoors option 4 6 1 Range 4 6 2 Control Examples Open Triangle Square Line...