12. Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build
up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER !
Disconnect from the mains before starting any
maintenance work
The front lens and mirror will require weekly cleaning as smoke-fluid tends to building up residues, reducing
the light-output very quickly. The cooling-fans should be cleaned monthly.
The interior of the fixture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
Dichroic colour filters, gobo wheels and the internal lenses should be cleaned monthly.
Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum-cleaner.
Important! Check the air filters periodically and clean before they become
clogged!
Clean the air filter in the fixture cover which is fastened to the cover by means of velcro fastener . Use a vacuum
cleaner, compressed air or you can wash them and put back dry.
After replacing the air filters, reset the elapsed time counter in the menu "Information" (Information--->Air Fil
-
ters---> Elapsed Time).
Replacing the fuse.
Before replacing the fuse, unplug mains lead.
1. Remove the fuse holder on the connection panel of the fixture with a fitting screwdriver from the housing
(anti-clockwise).
2. Remove the old fuse from the fuse holder.
3. Install the new fuse in the fuse holder (only the same type and rating).
4. Replace the fuseholder in the housing and fix it.
Replacing air filters.
Before replacing the fuse, unplug mains lead. Air filters are fastened to the cover by means of velcro fasteners.
1. Remove both stands by unscrewing two fastening screws on each stand.
2. Remove the top cover (1) by loosenig the four quarter-turn fasteners on the cover.
3. Remove the handle on the bottom cover by unscrewing the two fastening screws.
4. Remove the bottom cover by unscrewing the six fastening screws.
5. Clean the air filters (3) in the fixture covers which are fastened to the covers by means of velcro fastener.
Use a vacuum cleaner, compressed air or you can wash them and put back dry.
6. Screw both covers back on the fixture.
7. Screw handle back on the bottom cover.
8. Screw the stands back .
After replacing the air filters, reset the elapsed time counter in the menu "Information" (Information--->Air Fil
-
ters---> Elapsed Time).