29
Touch the warning icon or press the [ESCAPE] button to display error messages.
List of error and information messages:
Tilt Error 1
(Tilt Error 2)
This message will appear after the reset of the fixture if the mirror´s magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The mirror
is not located in the default position after the reset.
Pan Error 1
(Pan Error 2)
This message will appear after the reset of the fixture if the mirror´s magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The mirror
is not located in the default position after the reset of the fixture.
Colour Wheel Error 1 (Colour Wheel Error 2
)
The messages will appear after the reset of the colour wheel if this wheel is not located in the default position.
Cyan Error 1 (Cyan
Error 2)
The messages will appear after the reset of the cyan colour wheel if this wheel is not located in the default
position.
Magenta Error 1 (Magenta
Error 2)
The messages will appear after the reset of the magenta colour wheel if this wheel is not located in the default
position.
Yellow Error 1 (Yellow
Error 2)
The messages will appear after the reset of the yellow colour wheel if this wheel is not located in the default
position.
Prism Error 1
(Prism Error 2 )
The messages will appear after the reset of the prism wheel if this wheel is not located in the default position.
Zoom Error 1
(Zoom Error 2 )
The messages will appear after the reset of the zoom module if the zoom lens is not located in the default position.
Focus Error 1
(Focus Error 2 )
The messages will appear after the reset of the focus module if the focus lens is not located in the default.
Gobo Carousel Error 1
(Gobo Carousel Error 2 )
The messages will appear after the reset of the rotating gobo wheel if this wheel is not located in the default
position.
Gobo rotation Error 1
(Gobo Rotation Error 2 )
The messages will appear after the reset of the rotating gobo wheel if the rotating gobos are not located in the
default positions.
Static Gobo Error 1
(Static Gobo Wheel Error 2 )
The messages will appear after the reset of the static gobo wheel if this wheel is not located in the default position.
Clean Air Filters
The message informs that the item "Elapsed Time" in the "Fixture Information" menu is at 0 value. Clean air
filters and reset this counter.
White 1 Short Error (
White 2 Short Error/ White 3 Short Error/ White 4 Short Error)
Some white LEDs in the light source have short circuit or are disconnected.
White 5 Short Error (
White 6 Short Error/ White 7 Short Error/ White 8 Short Error)
Some white LEDs in the light source have short circuit or are disconnected.
Содержание ROBIN SilverScan
Страница 1: ...1 Version 1 4 ...