3.6 DMX-512 connection
The fixture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired
in parallel.
Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in
order to connect the controller with the fixture or one fixture with another.
DMX
-
output
DMX-input
XLR mounting-sockets (rear view):
XLR mounting-plugs (rear view):
Building a serial DMX chain
Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture. Always connect
one output with the input of the next fixture until all fixtures are connected. Up to 32 fixtures can be connected.
Caution:
At the last fixture, the DMX cable has to be terminated with a terminator. Solder a 120
Ω
resistor
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX output of the last fixture.
1
- Shield
2
- Signal (-)
3
- Signal (+)
4
- Not connected
5
- Not connected
1
- Shield
2
- Signal (-)
3
- Signal (+)
4
- Not connected
5
- Not connected