3.2 Changing the lamp
DANGER !
Install the lamp with the fixture unplug from mains !
To change the lamp
1. Disconnect the fixture from mains and allow it to cool at least 20 minutes.
2. Loosen the two quarter-turn fasteners (1) on a lamp cover and remove the lamp cover (2) to get into lamp
compartment.
3. Remove both fastons (3) from flat terminals of the lamp.
4. Holding the lamp by its ceramic base (4), carefully turn the lamp counter-clockwise by a quarter turn to release
the lamp from a lamp holder.
5 Holding the new lamp by its ceramics base (4), carefully insert the lamp into the lamp holder and turn it clockwise
by a quarter turn until you it reach a stop. Do not touch the lamp with bare hands. If necessary,
lamp can be cleaned with lint free towel before operation
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is
not de signed for. Please follow the lamp manufacturer‘s notes!
6. Slide both fastons (3) on the lamp terminals and check that fastons are fastened properly.
7
. Re-insert the lamp cover (2) and tighten the two quarter-turn fasteners (1) .
8. Connect the fixture to the mains.
9. Reset the "Lamp On Time” and "Lamp Strikes” counters in the menu "Information”.
This lamp emits ultra violet (UV) radiation and operates at high pressure!
Do not operate this fixture without properly fastened the lamp cover !
Unlock and remove the lamp
Lamp in locked position
Turn the lamp left
Lamp in unlocked position
Содержание ROBIN MegaPointe
Страница 1: ...1 Version 1 6 ...
Страница 35: ...35 Positions of fans ...
Страница 40: ...40 Dimensions mm ...
Страница 43: ...43 12 Photometric diagrams Lamp in Standard Mode ...
Страница 44: ...44 ...
Страница 45: ...45 ...
Страница 46: ...46 ...