9.Error and information messages
This message appears if you try to switch on the lamp within 5 minutes after having switched it off (the lamp is too
hot). The message will appear on the display if the lamp doesn't ignite within 28 seconds. The IMAGE SPOT 250
AT will store this information and automatically ignite the lamp when the 5 minutes period has expired.
Caution:
The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off (only if the lamp
was turned Off and On within 5 minutes,the message "HEAt" will appear).
The ignition of the lamp is seven times unsuccessful (the HEAt message appeared six times before), and the
display shows
"LA.Er"
, meaning that the lamp could be damaged or even missed, the fixture is overheating (this
can occur if the ambient temperature is 45° C or more) or there could be a failure on the ignitor or ballast.
Please place or replace the lamp, check the ambient temperature or contact your dealer if the situation was not
caused by the lamp.
Caution:
The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off.
The message informs you that the fixture was overheating and switched off. This message will appear on the
display if the fan speed operating "LOOF" was selected.
This messsage informs you that the main PCB does not communicate correctly with the Control Panel.
(rotating gobo-wheel error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the PCB).
The rotating gobo-wheel is not located in the default position after the reset.
(rotating gobo indexing error) This message will appear after the reset of the fixture and if the magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
PCB). The rotating gobo is not located in the default position after the reset.
(focus error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the PCB). The focus is
not located in the default position after the reset.
The message informs you that the fixture was overheating (occured if the ambient temperature is 45° C or more)
and that the relay switched off the lamp. This message will appear on the display until the temperature will be on
a suitable level, then the display will show the "HEAt" message meaning the lamp is too hot.
This message appears if the lamp lighting sensor is failed. Please, contact your dealer.
Caution:
The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off.
This message will appear if the fixture was shortly disconnect from the main.
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing
circuits malfunction (sensors failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the
main PCB). The yoke is not located in the default position after the reset.
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the
main PCB). The head is not located in the default position after the reset.
(Master error)The message informs you that the fixture was addressed as a master and DMX signal is connected
to its input.Disconnect the DMX controller from fixture's input and address the fixture as the master again.The
message appears after switching the fixture Off and On.
It will appear if the frequency of the mains is not standard 50 or 60Hz.