29
-Timer 2 -start
This function sets the start of the time period 2.Use the
[Up]
or
[Down]
buttons to specify the
start hour and press the
[Enter]
-button.Use the
[Up]
or
[Down]
buttons to specify the start minute
and press
[Enter]
.
-Timer 2-stop
This function sets the finish of the time period 2.Use the
[Up]
or
[Down]
buttons to specify the
stop hour and press the
[Enter]
-button.Use the
[Up]
or
[Down]
buttons to specify the stop minute
and press
[Enter]
.
If you wish to deactivate the Timer 2,set Ont2 ="Off" and OFt2 ="Off".
Note:Please, be sure that you don’t have any overlapping time periods to ensure the correct operation.
Don´t forget to choose the program which will be playing when the fixture operates (menu
Auto
).
If you want to modify the fixture clock or the time limits,do it when the program is not runnig,otherwise the
current time period will not be finished correctly.
How to set the time period operation:
1.Set
LAAu-
function to "
Off
"(menu
PerS,
submenu
LAPr)
.
2.Set the timer 1 and timer 2 (menu
StAL,
submenu
timr).
If you will use only one time period for operations,deactivate the timer 2.
3.
Choose the desired running program (menu
StAL,
submenu
Auto).
4.Deactivate the light level trigger (menu
StAL,
submenu
LiGt).
-
Light level trigger
By this menu you can set a light level for the stand- alone operation.If the light intensity falls below the specified
level then operation will start.
-Scanning the ambient light level
Press the
[Enter]
button to scan the current ambient light level (2-darkest,252-brightest).This
value is useful as a comparative level for setting both start and stop light levels for operation in
the stand-alone mode . The scanning takes about 7 seconds.By pressing the
[Mode]-
button
you can return to the menu.
-Light level - start
Use the
[Up]
and
[Down]
buttons to select the required light level when the operation is to be
started (3-251) and press
[Enter]
to confirm or
[Mode]
to cancel and return to the menu.Don´t
forget to choose the program which will be playing when the fixture operates (menu "Auto").
Important:
The values 0,1,2,252,253,254,255 do not affect the state of the fixture.
-Light level -stop
Use the
[Up]
and
[Down]
buttons to select the required light level when the operation is to be
finished (3-251) and press
[Enter]
to confirm or
[Mode]
to cancel and return to the menu.
Important:
The values 0,1,2,252,253,254,255 do not affect the state of the fixture.
If you wish to deactivate the light level trigger,set the "OnL"= 0 and "OFFL"= 255.