4.3 Fitting the lamp
DANGER !
Install the lamps with the device switched off only.
Unplug from mains before !
To insert the lamp (MSR 1200 AT SA):
1.Disconnect the fixture from power and allow it to cool.
2.Loosen the 2 quarter-turn fasteners marked "X, Y," on the lamp cover at the back of the head.
3.Gently pull the lamp cover with lamp holder out of the head.
4.Holding the lamp by its ceramic base,carefully pull the lamp straight out of the lamp socket.
5.Holding the new lamp by its ceramics base,gently insert the lamp to the lamp socket.Make sure that the lamp
is installed tightly into the lamp socket.
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed
for.Damages caused by non-observance are not subject to warranty. Please follow the lamp manufacturer‘s
notes!Do not touch the glass bulb bare hand during the installation!
6.Reinsert the lamp cover and tighten the 2 quarter-turn fasteners again.
7.Align the new lamp (see instructions below)
8.Reset "Lamp On Time" counter in "Fixture information" menu.
Do not operate this fixture with opened housing-cover!
Lamp cover
2 quarter-turn fasteners
Lamp
Lamp holder