28
1200 AT has been fabricated.
Resetable Hours --- The function shows the number of the operation hours that the COLORSPOT
1200 AT has been powered on since the counter was last reset.In order to reset this counter to
0,press [ENTER] twice.
Lamp On Time --- Select this submenu to read the number of the operation hours with the lamp on.
Total Hours --- The function shows the total number of the operation hours with the lamp on since
the COLORSPOT 1200 AT has been fabricated.
Resetable Hours --- The function shows the number of the operation hours with the lamp on that the
COLORSPOT 1200 AT has been powered on since the counter was last reset.In order to reset this
counter to 0,press [ENTER] twice.
Lamp Strikes --- Select this submenu to read the total number of the lamp strikes.
Total Hours --- The function shows the total number of the lamp strikes since the COLORSPOT
1200 AT has been fabricated.
Resetable Hours --- The function shows the number of the lamp strikes since the counter was last
reset.In order to reset this counter to 0,press [ENTER] twice.
Fixture Temperatures --- Select this submenu to read the temperatures of the fixture:
Current - Select this function to read the current temperatures of the fixture inside (Board
Temp.,Ambient Temp.,Near Lamp Temp.)
Maximum nonresetable - The function shows the max.temperatures of the fixture inside (Board
Temp.,Ambient Temp.,Near Lamp Temp.) since the COLORSPOT1200 AT has been fabricated.
Maximum resetable - The function shows the maximum temperatures of the fixture inside (Board
Temp.,Ambient Temp.,Near Lamp Temp.) since the respective counter was last reset.In order to
reset desired counter to 0,press [ENTER] twice.
Measurement points:
Board Temp. - temperature on the main board in the fixture base.
Ambient Temp. - temperature of the air which is sucked to the fixture base. This
temperature can be different from the real ambient temperature due to e.g. suction of
the hot air from the fixture head to the base if the fixture is hanging at the ceiling.Please
note that the ambient temperature should not exceed 40°C.
Near Lamp Temp. - temperature in the lamp chamber.
Fans Speed --- Select this function to read the actual speed of the fans(revolutions per minute):
Fan1 --- The fan cools the lamp peak
Fan 3 --- The fan on the rear left side of the head
Fan 5 --- The left fan at the CMY module
Fan 6 --- The right fan at the CMY module
Fan 7 --- The Fan iside the head
Fan 9 --- The fan on the front right side of the head
DMX Values --- Select this function to read DMX values of each channel received by the fixture.
Product IDs --- Select this function to read the MAC address or fixture code.
Software Version --- Select this function to read the software version of the fixture modules:
IC1 MB--- Main processor on the main board in the fixture base
IC2 MB--- Tilt processor on the main board in the fixture base
IC3 MB --- Pan procesor on the main board in the fixture base
IC4 MB--- EEprom on the main board in the fixture base
IC1 B1--- Shutter/conversion filter 3200K processor on the board 1 in the fixture head
IC2 B1--- Gobo wheel 1/gobo rotation/colour wheel processor on the board 1 in the fixture head
IC1 B2--- CMY processor on the board 2 in the fixture head
IC2 B2--- Effect wheel/effect rotation processor on the board 2 in the fixture head
IC1 B3--- Zoom/focus/frost processor on the board 3 in the fixture head
IC2 B3--- Gobo wheel 2/gobo rotation/iris processor on the board 3 in the fixture head
IC1 DS--- Display processor on the display module in the fixture base
IC2 DS--- Memory on the display module in the fixture base
Location of the fans,processors and temperature measuring points: