NOTE
: Each line of Emineres Remote connected to the LED output of the E-box Remote has to be terminated at
the last fixture.
EITHER
connect a 120 Ohm resistor between terminals D+ and D- in the last fixture,
OR
terminate via RDM as
described on page 11.
Ensure
ONLY
the last fixture in the line is terminated using
ONE
of the above methods!
Number of connected Emineres to one LED output of the E-box Remote depends on the type of Eminere
Remote and cable length.
The table states max. number of Eminere Remote modules connected to the E-box Remote
.
Max. number of Emineres Remote connected to the E-box Remote
Cable length *
Eminere Remote 1
Eminere Remote 2
Eminere Remote 3
Eminere Remote 4
25 m
20
10
6
5
50 m
16
8
5
4
75 m
13
6
4
3
100 m
10
5
3
2
* Cable length is the total cable length between E-box Remote and last connected Eminere Remote.
Example: Total cable length = L1+L2+L3+L4
Max. number of Eminere Remote modules connected to the one output of the E-box Remote/E-box Remote Basic is stated
in the following table.
Max. number of Emineres Remote connected to the one output of the E-box Remote
Eminere Remote 1
Eminere Remote 2
Eminere Remote 3
Eminere Remote 4
16
8
5
4
Example: if you want to connect 20 Emineres Remote 1 to the E-box Remote, you may connect 16 Emineres Remote 1 to
output 1 and 4 Emineres Remote 1 to output 2 (at total cable length of 25 m).