background image

18

 

 

7. DMX protocol

 

Version 1.0

 

Channel

 

DMX

 

Value

 

Function

 

Type of control

 

1

 

 

0-255

 

Red LEDs (Pixel 1)

 

Red LEDs saturation control (0-100%)

 

 

proportional

 

2

 

 

0-255

 

Green LEDs (Pixel 1)

 

Green LEDs saturation control (0-100%)

 

 

proportional

 

3

 

 

0-255

 

Blue LEDs (Pixel 1)

 

Blue LEDs saturation control (0-100%)

 

 

proportional

 

4

 

 

0-255

 

White LEDs (Pixel 1)

 

White LEDs saturation control (0-100%)

 

 

proportional

 

5

 

 

0-255

 

Red LEDs (Pixel 2)

 

Red LEDs saturation control (0-100%)

 

 

proportional

 

6

 

 

0-255

 

Green LEDs (Pixel 2)

 

Green LEDs saturation control (0-100%)

 

 

proportional

 

7

 

 

0-255

 

Blue LEDs (Pixel 2)

 

Blue LEDs saturation control (0-100%)

 

 

proportional

 

8

 

 

0-255

 

White LEDs (Pixel 2)

 

White LEDs saturation control (0-100%)

 

 

proportional

 

:

 

:

 

:

 

:

 

Depends 

on number 

of pixels N

 

 

0-255

 

White LEDs (Pixel N)

 

White LEDs saturation control (0-100%)

 

 

proportional

 

Содержание Anolis E-box Remote Basic

Страница 1: ...1 Version 1 4 ...

Страница 2: ...ounting 6 4 Eminere Remote modes 9 5 E box Remote menu 13 5 1 DMX Addr 13 5 2 Info 13 5 3 Personality 14 5 4 Test programs 15 5 5 Stand Alone 15 5 6 Special settings 15 6 Software update 16 7 DMX protocol 18 8 Technical specifications 19 9 Disposing of the product 20 10 Change Log 20 ...

Страница 3: ... its functions Do not permit operation by persons not qualified to operate the fixture Most damages are the result of unprofessional operation Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons Please use the original packaging if the fixture is to be transported If this device will be operated in any way different to the one described in this manual...

Страница 4: ...ons G Screws of terminal blocks cover H Terminal blocks cover 1 LED Output 1 cable gland M20x1 5 2 LED Output 2 cable gland M20x1 5 3 Power IN cable gland M20x1 5 4 DMX OUT cable gland M12x1 5 5 DMX IN cable gland M12x1 5 6 Ethernet OUT cable gland M12x1 5 7 Ethernet IN cable gland M12x1 5 View without top cover ...

Страница 5: ...5 Connection points ...

Страница 6: ...caps from cable glands before passing cables To keep declared IP rating of the device every cable gland has to be covered with the end cap if the cable gland is not used 5 Pass cables for DMX and Ethernet through cable glands M12x1 5 and connect them to the terminal blocks and tighten the cables in the cable glands 6 Pass cables for Power and LED outputs through cable glands M20x1 5 and connect th...

Страница 7: ...Data ground shielding Ethernet connection Pin 1 2 3 4 5 6 7 8 Function TX TX RX NC NC RX NC NC Eminere Remote connection Mark Function Wire Vcc LEDs Red D DATA Orange D DATA Black 0V LEDS White Ground Not connected Example of connection ...

Страница 8: ...nected to the E box Remote Cable length Eminere Remote 1 Eminere Remote 2 Eminere Remote 3 Eminere Remote 4 25 m 20 10 6 5 50 m 16 8 5 4 75 m 13 6 4 3 100 m 10 5 3 2 Cable length is the total cable length between E box Remote and last connected Eminere Remote Example Total cable length L1 L2 L3 L4 Max number of Eminere Remote modules connected to the one output of the E box Remote E box Remote Bas...

Страница 9: ...ult DMX address 1 changes can be done by the E box Remote or by RDM The Standard mode is set as default Pass Thr Pass through LED modules are switched to an internal parallel connection DMX addressing of connected LED modules has to be done manually by means of the Robe Universal Interface or its wireless version Robe Universal Interface WTX and the software RDM Manager Note RDM manager and DMX co...

Страница 10: ...to set DMX address and Personality for each LED module Click on the green arrow to save adjusted values DMX preset and number of used channels DMX address Note If only Emineres Remote 1 are connected to the E Box Remote there is no difference between DMX Preset 1 fixture mode and DMX Preset 2 pixel mode Occupied channels are displayed in the window DMX patch on the right side of the Control panel ...

Страница 11: ...urn on the predefined Demo mode You can modify it by setting the unit to a desired look via DMX and then save this via RDM by setting the Init position LEDs to 1 Last Eminere on each DMX line may be terminated by setting the Manufacturer PID Terminator active to 1 But ensure that the fixture is not already terminated with a 120 Ohm resistor as described on page 8 ...

Страница 12: ...12 The function Pixel swap from RDM control panel allows you to swap the pixel order Example ...

Страница 13: ... any node fixture on a network There cannot be 2 fixtures with the same IP address on the network Default Address This address is derived from fixture s MAC address and cannot be changed Confirm the item Set Address to select this address Custom Address IP address consists of four decimal numbers each ranging from 0 to 255 separated by dots e g 172 16 254 1 Each part represents a group of 8 bits o...

Страница 14: ...the standard DMX cable Wireless DMX signal is received by means of the inbuilt wireless DMX module Wireless Out DMX the fixture receives wireless DMX and sends the signal to its wired DMX output The fixture behaves as a Wireless Wired adapter Ethernet DMX signal is received by means of the Ethernet cable If wireless DMX module is installed Ethernet Settings use the menu item to select and set desi...

Страница 15: ...to run a test sequence without an external controller which will show you some possibilities of using the E box Remote in conjunction with LED modules Colors the item runs a colour changing of all LEDs in a loop Standard mode has to be selected from the menu E box mode Pixels the itemruns a pixel program in a loop Standard mode has to be selected from the menu E box mode number of pixels depends o...

Страница 16: ...ace Robe Universal Interface WTX and the ROBE RDM Uploader software The ROBE Uploader is a software for automatized software update of ROBE fixtures The ROBE Uploader switches E box Remote to the update mode automatically Please see https www robe cz robe uploader for more information about the ROBE Uploader Examples of connections for software update 1 By means of the Ethernet connection ...

Страница 17: ...17 2 By means of the Robe Universal Interface Robe Universal Interface ...

Страница 18: ...portional 4 0 255 White LEDs Pixel 1 White LEDs saturation control 0 100 proportional 5 0 255 Red LEDs Pixel 2 Red LEDs saturation control 0 100 proportional 6 0 255 Green LEDs Pixel 2 Green LEDs saturation control 0 100 proportional 7 0 255 Blue LEDs Pixel 2 Blue LEDs saturation control 0 100 proportional 8 0 255 White LEDs Pixel 2 White LEDs saturation control 0 100 proportional Depends on numbe...

Страница 19: ...fixture Control 2 row LCD display 4 buttons Supported protocols USITT DMX 512 RDM ArtNet MA Net MA Net2 sACN Kling Net Operating modes Pixel 12 LEDs or Fixture mode Connection Power IN terminal block Ethernet IN OUT terminal block DMX IN OUT terminal block LED Outputs terminal block Operating ambient temperature range 20 40 C 4 F 104 F Cooling System convection Protection factor IP65 CE Suitable f...

Страница 20: ...escription of changes 1 1 26 01 2022 Description of connection blocks modified 1 2 24 02 2022 Description of the fixture corrected 1 3 14 03 2022 Design of the manual changed 1 4 07 04 2022 Menu DMX preset added menu Devices removed Eminere connection changed April 7 2022 Specifications are subject to change without notice Copyright 2021 2022 Robe Lighting All rights reserved Made in CZECH REPUBLI...

Отзывы: