36
37
Tempeatures
- Maximum ambient temperature: 40° C
- Maximum housing temperature of the head: 130° C
Minimum distances
- Min. distance from flammable surfaces: 1.2 m
- Min. distance to lighted object: 2 m
Dimensions and weight
- Weight - Colorspot 1200 AT (magnetic ballast):
51,5 kg
- Weight - Colorspot 1200E AT (electronic ballast): 42 kg
Accessories:
Gobo-set 10 (No. 15050019) ....................................................... 1 piece
Mounting bracket Omega CL assembled (No. 99010420) .......... 2 pieces
Optional acesories:
Remote control IR (No. 13050419)
Flash Cable RS232/DMX (No. 13050624)
13. Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on or
within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will not only ensure the
maximum light-output, but will also allow the fixture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should alcohol
or solvents be used!
DANGER ! Disconnect from the mains before starting any maintenance work
The front objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the light-output
very quickly. The cooling-fans should be cleaned monthly.
The interior of the fixture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
Dichroic colour filters, CMY lamelas,gobo wheels and the internal lenses should be cleaned monthly.
Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum-cleaner.
Important! Check the air filters periodically and clean before they become
clogged!
Clean the air filters from the front fans with a vacuum cleaner, compressed air or you can wash them and put back dry.
Replacing the air filters.
1)Disconect the fixture from power.
2)Remove both top and bottom cover of the head (by loosening the 4 quarter-turn fasteners on each cover)
3)Remove the air filters (they are fixed with a velcro fastener) from grids.
4)Clean or replace the air filters.
5)Place the filters on the grid and put head cover back.
6)Reset the elapsed time counter in menu Fixture information (Fixture Information--->Air Filters---> Elapsed
Time.
Bam angle 13° with frost, distance=5 m
Beam angle 42° with frost, distance=5 m