34
35
Gobo 1 Index Error 1 (Gobo 1 Index Error 2)
The messages will appear after the reset of the gobo wheel 1 if the rotating gobo wheels are not located in the default
positions.
Gobo 2 Wheel Error 1 (Gobo 2 Wheel Error 2)
The messages will appear after the reset of the gobo wheel 2 if this wheel is not located in the default position.
Gobo 2 Index Error 1 (Gobo 2 Index Error 2)
The messages will appear after the reset of the gobo wheel 2 if the rotating gobo wheels are not located in the default
positions.
Effect Wheel Error 1 (Effect Wheel Error 2)
The messages will appear after the reset of the effect wheel if this wheel is not located in the default position.
Effect Index Error 1 (Effect Index Error 2)
The messages will appear after the reset of the effect wheel if the rotating effect wheels are not located in the default
positions.
Iris Error 1 (Iris Error 2)
The messages will appear after the reset of the iris if the iris lamellas are not located in the default positions.
Cyan Lamella Error 1 (Cyan Lamella Error 2)
The messages will appear after the reset of the CMY module if the cyan lamellas are not located in the default positions.
Magenta Lamella Error 1 (Magenta Lamella Error 2)
The messages will appear after the reset of the CMY module if the magenta lamellas are not located in the default positions.
Yellow Lamella Error 1 (Yellow Lamella Error 2)
The messages will appear after the reset of the CMY module if the yellow lamellas are not located in the default positions.
CTO Lamella Error 1 (CTO Lamella Error 2)
The messages will appear after the reset of the CTO module if the CTO lamellas are not located in the default positions.
Zoom Error 1 (Zoom Error 2)
The messages will appear after the reset of the zoom module if the module is not located in the default position.
Focus Error 1 (Focus Error 2)
The messages will appear after the reset of the focus module if the module is not located in the default position.
Pan Error 1 (Pan Error 2)
The messages will appear after the reset of the yoke if the yoke is not located in the default position.
Tilt Error 1 (Tilt Error 2)
The messages will appear after the reset of the head if the head is not located in the default position.
12. Technical specifications
Power supply:
Magnetic ballast - ColorSpot 1200 AT:
Voltage: ........................................ 208/230/250V AC, 50/60Hz ~
Main fuses:
Live fuse: ......... T10A@230V
Neutral fuse: .... T10A@230V
Electronic ballast - Colorspot 1200E AT:
Voltage: ....................................... 100/120/208/230/250V AC, 50/60Hz ~
Main fuses:
Live fuse: ......... T10A@230V
Neutral fuse: .... T10A@230V
Live fuse: ......... T20A@120V
Neutral fuse: .... T20A@120V
Power consumption: ..................... 1600 VA
Lamp:
Philips MSR 1200 SA, base: GY22, colour temperature: 5600 K, average lamp life: 750 h
Optical System:
- High luminous-efficiency parabolic reflector